Inter-machine reliability of the Biodex and Cybex isokinetic dynamometers for knee flexor/extensor isometric, concentric and eccentric tests. Phys Ther Sport. 2015;16(1):59-65.Alvares, J. B. d. A. R. et al. Inter-machine reliability of the Biodex and Cybex isokinetic dynamometers for knee...
Isokinetic dynamometry is a widely used tool for measuring muscle strength in clinical intervention and rehabilitation as well as research in children.To assess the test-retest reliability of knee flexor/extensor strength using the Biodex Multi-Joint System 4 Isokinetic Dynamometer in children.Peak isom...
[Methods] Measurement of isokinetic muscular function of both flexor and extensor muscles was performed at the angular velocities of 60°/sec and 180°/sec using a Biodex system 3, before and after application of Kinesio taping to the rectus femoris, vastus medialis, vastus lateralis, and ...
sagittal plane knee translation of both knees was measured with the CA-4000 system (Orthopaedic System Inc., CA) during maximum muscle forces on the Biodex machine (Biodex Medical Systems Inc., Shirley, NY) at an angular velocity of 60 deg/sec. Moderate correlations were found between the ...
(2014). Inter-machine reliability of the Biodex and Cybex isokinetic dynamometers for knee flexor/extensor isometric, concentric and eccentric tests. Phys Ther Sport 15: 131-216.Inter-machine reliability of the Biodex and Cybex isokinetic dynamometers for knee flexor/extensor isometric, concentric ...
Sagittal translation of the tibia was examined in a static test with 90 N force at 20掳of knee flexion and dynamically during knee extension in a Biodex machine using increasing quadriceps torque in six healthy volunteers. The translation increased in a non-linear fashion with increasing torque. ...
PURPOSE: The present study aimed to compare the results of isokinetic testing of knee extensor and flexor muscles by using Cybex 6000 and Biodex 3 dynamometers (intermachine reliability) at 60°/s, 180°/s, and 240°/s. MATERIALS AND METHODS: After written informed conse...
Inter-machine reliability of the Biodex and Cybex isokinetic dynamometers for knee flexor/extensor isometric, concentric and eccentric tests Knee extensor/flexor tests were performed using Biodex and Cybex isokinetic dynamometers.Isometric peak torque measures were similar between devices.Concen... DARAJ ...
This study concentrated on two sets of data: (1) highest peak torque, comparing the highest concentric peak torque value produced on each machine; and (2) clinical peak torque comparing the highest peak torque values produced on the Cybex and Biodex with the mean peak torque for the given ...
Inter-machine reliability of the Biodex and Cybex isokinetic dynamometers for knee flexor/extensor isometric, concentric and eccentric tests. Phys. Ther. Sport 2015, 16, 59–65. [Google Scholar] [CrossRef] [PubMed] Duarte, J.P.; Valente-Dos-Santos, J.; Coelho, E.S.M.J.; Couto, P....