Hand-held dynamometerIsometric strengthShoulder rotationReliabilityThe purposes of this study were to compare isokinetic dynamometer (IKD) and hand-held dynamometer (HHD) based protocols for determining isometric shoulder rotation strength and to quantify the variation that could be expected when inter...
Isokinetic Dynamometer Isomed 2000, supplied by Isomed GmbH, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/result/isokinetic dynamometer isomed 2000/product/Isomed GmbH ...
The evaluation on the isokinetic dynamometer provides these controlled, accurate, standardized and quantifiable data, as long as it is possible to know all the details of the instrument’s application protocol. With that, the aim of this study was to identify, through a systematic literature ...
The isokinetic dynamometer was calibrated according to the manufacturer's directions prior to the evaluation. The patients performed a warm up walk of 10 min before the evaluation. We evaluated the concentric torques of the knee at speeds of 60 degrees/s and 180 degrees/s. The evaluations were...
This protocol should also help optimise physical medicine and rehabilitation practices: the more systematic use of the isokinetic dynamometer as a technique associated with, and integrated into the conventional rehabilitation protocol would allow an objective evaluation of the rehabilitation benefits and shoul...
Isokinetic muscle strength test Isokinetic dynamometer (CON-TREX, Physiomed, Germany) was used to evaluate the strength of elbow extensor and flexor muscles on the self-reported dominant side by experienced personnel based on the instruction manual. The test parameters of the isokinetic test protocol ...
(Miyamoto et al.2011). Each participant lay on an isokinetic dynamometer (CON-TREX, CMV AG, Switzerland) with the right knee and hip joints fully extended. The right foot was tightly secured to the dynamometer’s footplate, and the right thigh was fixed to the dynamometer’s bench with ...
The axis of rotation of the dynamometer arm will be posi- tioned just lateral to the lateral femoral epicondyle. Conventional concentric and eccentric continuous iso- kinetic tests will be used. During concentric and eccentric tests, the subjects will continuously push the lever arm of the ...
The experimental protocol was approved by the Ethical Committee of the University of Verona (protocol number: 2019-UNVRCLE-0193291). 2.2. Experimental procedures Dynamometry. Maximal knee extensions were performed on an isokinetic dynamometer (Cybex, Humac Norm, division of Lumex Inc., Ronkonkoma, ...
As a consequence of dynamometer measurement, the strength of the psoas muscle decreased significantly after OLIF surgery from the preoperative value to postoperative values of 30.61% at 2 days and 22.60% at 1 week after OLIF surgery. However, the decrease was insignificant from 1 month after surge...