The design inter-storey drift ratio ranges from 0.1 to 2.5%. Five EC-8 spectrum-compatible ground motions of 0.48 times acceleration due to gravity, and medium type soil are considered for the inelastic time history analyses. The proposed relation is validated with new buildings of different ...
2)inelastic storey drift limit弹塑性层间位移角限值 3)allowable value of drift angle位移角限值 1.And the allowable value of drift angle of frequent earthquake of the out-of-code long-span hangar is discussed primarily.介绍了超限大跨机库结构设计要点和应采取的相应抗震措施,主要针对屋盖结构选型、平...
层间位移角应至少为0.02弧度。 翻译结果2复制译文编辑译文朗读译文返回顶部 楼的漂流物角将是至少 0.02 弧度。 翻译结果3复制译文编辑译文朗读译文返回顶部 层漂移角度应 0.02 弧度的最低限度。 翻译结果4复制译文编辑译文朗读译文返回顶部 interstorey偏航角将是至少0.02弧度。 翻译结果5复制译文编辑译文朗读译文返回顶...
The BP systems generally reached an interstorey drift exceeding 2.5%, while the S-DT and DTP systems reached drifts of 0.6% and >1.2%, respectively. The BP systems also exhibited more ductile failure modes than the S-DT and DTP systems, involving withdrawal failure of the wood screws. ...
accommodate the required interstorey drift angle within the connection elements问题补充:匿名 2013-05-23 12:21:38 容纳连接元件中所需的层间位移角 匿名 2013-05-23 12:23:18 容纳在连接元素内的必需的interstorey偏航角 匿名 2013-05-23 12:24:58 容纳必需的interstorey偏航角在连接元素之内 ...
In order to estimate the inelastic interstorey drift of cold-formed steel (CFS) framed structures under collapse level earthquakes, the deflection amplification factor ηp is employed in this paper to compute the maximum interstorey drift ratio (IDRmax) from an elastic analysis. For this purpose,...
11.Dynamic Reliability Calculation of Interstorey Drift and Storey Shearing Force for Multi-storey and High Building Structures多高层建筑结构层间位移和层剪力的动力可靠度计算 12.TSL Coordinates. Boundary Conditions. Shear Layer Categories.薄剪力层座标,边界条件,剪力层种类。 13.The shear stress in inter...
ajoined 加入 [translate] aKeywords: Maximum inter-storey drift ratio; Equivalent static force; Reinforced concrete frame structure; Blast loading 主题词: 最大相互层漂泊比率; 等效静态力量; 钢筋混凝土框架结构; 疾风装货 [translate] 英语翻译 日语翻译 韩语翻译 德语翻译 法语翻译 俄语翻译 阿拉伯语翻译 ...
aFor example most multistorey buildings in practice would have a shear model used with beam rotations and axial stiffness suppressed, the P-delta effect of secondary moments can only be neglected if inter-storey drift is less than 0.01 times the storey height. 例如多數multistorey大廈實踐上將有剪...
2) inelastic storey drift limit 弹塑性层间位移角限值 3) elastic-plastic 弹塑性 1. Iterative method for determination ofelastic-plasticstress singularities near an interface edge; 界面端弹塑性应力奇异性的迭代计算方法 2. The experimental study of earthelastic-plasticand the previous consolidation pressu...