INS-41112 Specified network interface doesnt maintain connectivity across cluster nodes. PRVF-6020 : Different MTU values used across network interfaces in subnet 专家解答 查看2节点相关网卡的MTU参数,发现2边不一致, root@hxcrmdb1[/tmp] # lsattr -El en18 alias4 IPv4 Alias including Subnet Mask True...
安装grid软件时报错INS-41112错误,例如以下图所看到的: 两节点进行ping測试。分别ping“公有IP”和“私有IP”,两节点ping通正常后,按例如以下方式配置: 1、两节点进行SSH验证 节点1: [grid@test1 ~]$ ssh rac2priv date --验证节点2私有IP The authenticity of host 'rac2priv (192.168.56.73)' can't be ...
grid报INS-41112错误 一、验证ssh 二、关闭不必要的服务 # chkconfig NetworkManager off # sed -i 's/SELINUX=enforcing/SELINUX=disabled/' /etc/selinux/config # chkconfig iptables off
安装grid软件时报错INS-41112错误,例如以下图所看到的: 两节点进行ping測试。分别ping“公有IP”和“私有IP”,两节点ping通正常后,按例如以下方式配置: 1、两节点进行SSH验证 节点1: [grid@test1 ~]$ ssh rac2priv date --验证节点2私有IP The authenticity of host 'rac2priv (192.168.56.73)' can't be ...
[FATAL] [INS-41112] Specified network interface doesnt maintain connectivity across cluster nodes.CAUSE: Installer has detected that network interface eth<n> does not maintain connectivity on all cluster nodes.ACTION: Ensure that the chosen interface has been configured across all cluster nodes....
[INS-41112]Specified network interface doesnt maintain connectivity across cluster nodes 首先尝试在节点间ping 各个IP 地址没有问题。 因为使用安装程序做的SSH 验证,所以尝试测试ssh远程连接是否还需要确认: [grid@rac2 ~]$ ssh rac2 dae bash: dae: command not found ...
rac安装grid报INS-41112错误 查看原文 PowerDesigner打开pdm文件时报“打印错误”(解决) 原创作品,出自“深蓝的blog”博客,欢迎转载,转载时请务必注明出处,否则追究版权法律责任。深蓝的blog:http://blog.csdn.net/huangyanlong/article/details/49700845 打开pdm文件:报错: 解决: 开启Print Spooler服务。 (1)、找到...
安装11.2.0.3.0的RAC,在安装GRID时报错: [INS-41112] Specified network interface doesnt maintain connectivity across cluster 1、首先检查各节点/etc/hosts,发现没问题 2、setup安装成功,但是ssh验证,需要确认 3、检查发现是没有关闭防火墙 (配置RAC一定要仔细)...
[INS-41112]Specified network interface doesnt maintain connectivity across cluster nodes 首先尝试在节点间ping 各个IP 地址没有问题。 因为使用安装程序做的SSH 验证,所以尝试测试ssh远程连接是否还需要确认: [grid@vdb1 ~]$sshvdb1date# 验证vdb1sshThu Aug715:20:44CST2014[grid@vdb1~]$sshvdb2date# 验证...
The following can also be part of the output: PRVG-11850 : The system call "string" failed with error "number" while executing exectask on node "racnode" DETAILS [INS-41112] is a high level error number, the workarounds/solutions depend on the error code from lower layer, however, [IN...