In order to run a trace against SQL Server you must be a member of sysadmin fixed server role or have the ALTER TRACE permission. 简介:SQL用PROFILER时产生的权限问题。不用大开到SYSADMIN的权限吧。 用以下方法完美解决。只给TRACE权限。 SQL Server Profiler and ALTER TRACE permission Yesterday, I w...
Ab SQL Server 2022 (16.x) Kumulatives Update 6 können Sie die Transaktionsreplikation mit der Microsoft Entra-Authentifizierung konfigurieren – allgemein verfügbar (GA) im Kumulativen Update 12. Always Encrypted mit Secure Enclaves Unterstützung für JOIN, GROUP BY und ORDER BY sowie ...
1. Determine what version of SQL Server you have and double-click the link below to download the zip file of SQL templates. In the zip file, click on the TRACETMPL folder and double-click on the .tdf file for your version and SQL Profiler will automati...
secondary database, the query is recompiled. This issue occurs because the statistics are not propagated correctly from the primary server to the secondary server. If you run the profiler trace, you will find something similar with the following aboutStatManwhich means SQL server is querying ...
To check for historical evidence of a blocked redo, open the AlwaysOn_health Xevent trace files on the secondary replica by using SSMS. Look for lock_redo_blocked events. Use Performance Monitor to actively monitor blocked redo impact to recovery que...
A USE database statement is not allowed in a procedure, function or trigger. A week this year Against a week this time last year in SQL (NOT MDX) A WITH keyword and parenthesis are now required Accent Sensitivity Access Code - DELETE Statement with DISTINCTROW and T-SQL Access Now() v...
It should be clear to the reader at this point that in order to obtain good SQL Server batch execution performance, the following two things need to happen: Query plans should be reused whenever possible. This avoids unnecessary query compilation costs. Plan reuse also results in better plan ca...
Take note of the result of the above SQL query. Proceed with safely deleting one of the duplicated user ids. Run the below queries in order: 1234DELETE FROM cwd_membership WHERE child_user_id = <duplicated_id>; DELETE FROM cwd_user_attribute WHERE user_id ...
Run the app, either on your server or on your development machine by using F5. Re-create the exception. Open the Application Insights Search telemetry window in Visual Studio. While debugging, select the Application Insights dropdown box. Select an exception report to show its stack trace. To...
The flatcc compiler is implemented as a standalone tool instead of extending Googles flatc compiler in order to have a pure portable C library implementation of the schema compiler that is designed to fail graciously on abusive input in long running processes. It is also believed a C version ...