Implant stability related to insertion torque force and bone density:An in vitro study, J Prosthet Dent, 74:608-612,1995。 :J. Tricio, D. van Steenberghe, D. Rosenberg, and L. Duchateau, "Implant stability related to insertion torque force and bone density: An in vitro study," The ...
Factory Direct Sale Universal Dental ratchet torque wrench Dental Implant Torque Wrench $16.00 - $23.50 Min. order: 200 pieces Ready to ship Sinus Lift Bur Dental Implant Drill Bit Dental Sinus Lift Kit dental tool drill $1.99 - $15.99 Min. order: 100 pieces Fixture screw driver Cover screw...
Results. Closing torque values were found to be significantly different between operators and between implant systems (P <.0001). Mean closing torque values of 9 operators performing 5 closures for 5 systems ranged from 7 to 14.6 N/cm for habitual closures and from 9.4 to 19.9 N/cm for ...
(2015) Effect of insertion torque on titanium implant osseointegration: an animal experimental study. Clin Oral Implants Res 26(2): 191-196.Duyck J, Roesems R, Cardoso MV, Ogawa T, De Villa Camargos G, Vandamme K. Effect of the insertion torque on titanium implant osseointegration: an ...
Recommended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res 2006; 17: 109-14.Motoyoshi M, Hirabayashi M, Uemura M, Shimizu N. Recom- mended placement torque when tightening an orthodontic mini-implant. Clin Oral Implants Res 2006;17:109--14....
Materials and methods Thirty micro-implants of three types (diameter 1.5 mm, Types A, B, C) were assessed. All micro-implants were manually driven into artificial bones at an 8-mm depth. The insertion torque (IT), pullout strength (PS), and gripping volume (GV) of each type were ...
Implant Insertional torque values predict outcomes. J Oral Maxillofac Surg 2011;69:1344-1349.Walker, L. R., Morris, G. A., & Novotny, P. J. (2011). Implant inser‐ tional torque values predict outcomes. Journal of Oral and Maxillofacial Surgery, 69(5), 1344-1349. https://doi.org/...
Gomes EA, Tiossi R, Faria AC, Rodrigues RC, Ribeiro RF. Torque loss under mechanical cycling of long-span zirconia and titanium- cemented and screw-retained implant-supported CAD/CAM frame- works. Clin Oral Implants Res. 2014;25:1395-1402....
Development of a new implant primary stability parameter: Insertion torque revisited. Clin. Implant. Dent. Relat. Res. 2013, 15, 637-644. [CrossRef] [PubMed]Degidi M, Daprile G, Piattelli A, et al. Development of a new implant primary stability parameter: insertion torque revisited [ J...
The modification of implant tightening components for use with torque driversdoi:10.1016/S0022-3913(96)90468-0Stephen M Cameron and Michael R CraddockThe Journal of Prosthetic Dentistry