Supplier Homepage Products DC Isolation Switch IP66 UV Resistance Earth Terminal IEC60947-3, As60947.3 DC Isolator Enclosure with Mc4 Related Categories Fuse Rotary Switch Combination Switch Electrical Isolator Switch Safety Isolation Switch Isolation Disco...
IEC 60947-7-3产品型号说明书 4 (4) mm², 6.3 A, fuse terminal block for 16 (16) mm², 40 A, basic fuse terminal block
IEC60947-3,AS60947.3 利用率类别 DC-PV2/DC-PV1/DC-21B 杆 4P 额定频率 50/60赫兹 额定工作电压 (Ue) 300V、600V、800V、1000V、1200V 额定绝缘电压 (Ui) 1200V 额定短时耐受电流 (Icw) 1kA,1S 额定脉冲耐压 (Uimp) 8. OkV 过电压类别 ...
1 Eaton Heavy Duty Safety Disconnect Switch 30A 600 Vac/V 3 Pole Type 1 DH361UGK ① EATON CUTLER-HAMMER 10250T201N Oiltight Indicator Light FREE SHIPPING! 1 EATON CUTLER HAMMER BAB3020 BAB3020H BA BAB CIRCUIT BREAKER 3P 20 AMP WHITE 1 ?” NPT FEMALE 90 Degree Elbow Eaton Weatherhead C...
For a system that is being built to IEC-60947, what color should wire be that is carrying foreign voltage that will not be turned off by the enclosure's main disconnect? I found a chart with the other IEC color codes but it doesn't list "foreign voltage." In the USA, it's orange...
Moeller Motor Disconnect Switch P1-25/12/SVB-NA #49720 Moeller motor controller part no. PKZM0-6.3 Moeller motor controller part no. PKZM0-2.5 MOELLER MOTOR CONTROL 4.0-6.3 A PKZMO-6.3-T * OUT OF BOX* Moeller Motor - Protective Circuit Breaker PKZMO-0-63 ...
Supply disconnecting devices serve to disconnect the electrical supply of the factory from the inside of the control panel, for example, when maintenance person open the control panel and perform some kind of maintenance. By this measure, the maintenance personnel can perform the maintenance without ...
organizations, from easy installation to our various colors for quick circuit identification. We offer standard feed through terminal blocks with spring clamps or screw clamps, as well as disconnect, fuse holder , and power distribution. Our multi-level terminal blocks provide easy 3-wire sensor ...
IEC 60947 1 the wording of the test of the voltage drop improved in 8 4 4 the wording of the short time withstand current test improved in 8 4 6 Annex D with additional requirements for test disconnect terminal blocks added The scope modified accordingly This standard shall be read in ...
ITE FR356-1 600 Amp, 600 Volt, Fused, Nema 3R DisconnectITE Cordon Breaker 90 amp trip Type ET frame CK 100K IRITE INDOOR DISCONNECT SWITCH 1200 AMP 240V 3P 4W SN428L FUSIBLEKP2B120 ITE Siemens Circuit Breaker 600V 1200A 2P KP2 ...