The 3-year rate of inappropriate ICD therapy atrial flutter/fibrillation was 8% in the single-chamber versus 3% in the dual-chamber patients (P = 0.006) (Figure 1) with adjusted dual: single hazard ratio of 0.47, p=0.03. There was no difference in appropriate shocks or mortality between ...
ICD implantation for primary or secondary prevention of sudden cardiac death has been shown to improve survival in patients with ejection fractions of less than 35%. Reducing appropriate and inappropriate shock therapy has been shown to reduce morbidity in these patients. The role of an atrial lead...
Discover our innovative ICD devices for reliable cardiac rhythm management & improved patient outcomes. From the Ulys to the Edis, explore our range now.
ICD介绍 植入式心律转复除颤器ImplantableCardioverterDefibrillator 美敦力(中国)有限公司 心脏猝死 •在美国,心脏猝死每年发病率为250,000至350,000,平均存活率仅为5%。•心脏病专家可以辨别这种高危病人,以防止心脏骤停。心脏猝死是主要致死病症之一 300,000 250,000 200,000 150,000 100,000 50,000 0 爱I滋...
14.Electrophysiological Effects of Ibutilide and Its Efficacy for Termination of Atrial Fibrillation/Flutter;伊布利特对心脏电生理的影响及转复心房颤动/扑动心律的有效性 15.Changing Levels of Myocardial Cell Apoptosis after Atrial Fibrillation Converted to Sinus Rhythm in a Goat Model;山羊心房颤动模型复...
Background A significant number of patients with an implantable cardioverter/defibrillator (ICD) for primary prevention receive inappropriate shocks. Previ... Jörg,Otto,Schwab,... - 《Clinical Research in Cardiology》 被引量: 6发表: 2015年 A Case of Inappropriate Therapies for Atrial Flutter From...
Medgadget reports that medical device manufacturer, BIOTRONIK, has gained FDA approval for the Lumax 740 DX System. The implantable cardioverter defibrillator is the first in the world that will allow certain patients the benefit of atrial sensing without the requirement for a second wire to r...
What ICD-10 Codes Are Used for Atrial Fibrillation? The categorization of Atrial Fibrillation, an irregular and often rapid heart rate, involves a variety of Atrial Fibrillation ICD codes. Here are some commonly used ones: I48.0- Paroxysmal atrial fibrillation: This code refers to AF that begins...
INAPPROPRIATE THERAPY FOR ATRIAL FLUTTER/FIBRILLATION IS LOWER WITH DUAL- THAN SINGLE-CHAMBER ICD IN MADIT-CRT ICD implantation for primary or secondary prevention of sudden cardiac death has been shown to improve survival in patients with ejection fractions of less than 35%. Reducing appropriate and...
Elective cardioversion, using the same external defibrillating devices, was also a commonly used therapy for the conversion of ventricular tachycardia, atrial fibrillation, and atrial flutter to more normal rhythms. These cardioversion devices utilized a synchronization of the defibrillator discharge with ...