Purpose The purpose of this study is to provide data for the calibration of the recent RefleXionTM biology-guided radiotherapy (BgRT) machine (Hayward, CA, USA) following the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) TRS-483 code of...
IAEA TRS 483stereotactic radiosurgeryTG‐21The GammaPod is a novel dedicated prone breast stereotactic radiosurgery (SRS) device recently developed at the University of Maryland Medical Center. This device utilizes multiple rotating Co sources to create highly conformal dose distributions for breast ...
The IAEA TRS 483 protocol for the dosimetry of small static fields in radiotherapy was used to calculate output factors for the Elekta Synergy linac at the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). Small field output factors for both square and circular fields were ...
TRS-483 Acuros® XB Small field dosimetry Field output factors 1. Introduction In the last decades, photon radiotherapy systems integrate complex dose calculation algorithms for treatment planning. The introduction of Monte Carlo, Boltzmann, and model-based convolution methods has considerably improved ...
Dosimetry of small static fields used in external photon beam radiotherapy: Summary of TRS‐483, the IAEA–AAPM international Code of Practice for referenc... Purpose A joint IAEA/AAPM international working group has developed a Code of Practice (CoP) for the dosimetry of small static fields use...
TRS‐483Purpose A joint IAEA/AAPM international working group has developed a Code of Practice (CoP) for the dosimetry of small static fields used in external megavoltage photon beam radiotherapy, published by the IAEA as TRS‐483. This summary paper introduces and outlines the main aspects of ...
P70 - Implementation of IAEA TRS 483 in small field dosimetry of Leksell gamma knife icon: transition from IAEA TRS 398 to IAEA TRS 483doi:10.1016/S1120-1797(22)00372-6J. NovotnyElsevier LtdPhysica Medica
TRS‐483reference dosimetrysub‐rLCPE photon fields10 x 2 cm2 field size6 MV FFF beamThe purpose of this study is to provide a calibration methodology for radiation therapy machines where the closest field to the conventional reference field may not meet the lateral charged particle equilibrium (...
The comparison result of the determination of the absorbed dose to water using AAPM TG-148 and IAEA TRS 483 protocol has a deviation of 0.2%.O A FirmansyahA F FirmansyahS I SunaryatiW E WibowoConference on Fundamental and Applied Science for Advanced Technology (ConFAST 2019): Yogyakarta(I...
Determination of Effective Measurement Point and Validation of Collimator Output Factors for Gamma Knife Icon Unit using IAEA TRS-483 Protocoldoi:10.1016/j.ijrobp.2020.07.678S.L. CyriaJ. LiuE. CalugaruJ. ChangInternational Journal of Radiation OncologyBiologyPhysics...