Solenoid Valve structure Solenoid Other attributes application General place of origin Zhejiang, China power Solenoid customized support OEM model number EVR 10 Product Name Refrigeration Solenoid Valve Valve Model EVR 10 Port Size 1/2'', 5/8'' Connection Solder (ODF) Operation Diaphragm Pilot Operat...
Liquid Line Solenoid Valve liquid slugging LLSV lock out circuit Locked Rotor Amperage Low Side Float low voltage controls LRA magnetism MAT Mechanical Cooling MegOhm Mercury mercury bulb thermostat Metering Device MFD micron micron gauge Mid Seated migration mineral oil Minimum Fresh Air Mixed Air MO...
PUMPDOWN - Process of pumping refrigerant out of the evaporator and suction line at the end of the on- cycle by closing a solenoid valve in the liquid line and letting the compressor shut-off by the low pressure control. PSYCHROMETER - A devices having both a dry and wet bulb thermometer....
A first solenoid-operated, discharge-line control valve () is moved between open and closed positions to control fluid flow in the discharge fluid line () between the compressor () and the condenser (). A second solenoid-operated, liquid-line control valve () is moved between open and ...
ConnectionMale ThreadLiquid temperature1~95°C Character of structure 1.Inlay contact switch, the motor is power off after the valve completes open and close, so it has long service life and power saving, but is also safe. 2.The valve body is separated...
Process of pumping refrigerant out of the evaporator and suction line at the end of the on- cycle by closing a solenoid valve in the liquid line and letting the compressor shut-off by the low pressure control.R R Value (insulation) A measure of the capacity of a material to resist heat...
RL - refrigerant liquid RLA - Rated Load Amperes RM - room RS - refrigerant suction RTN - return RV - relief valve S - switch SA - shock absorber, supply air SAT - supply air temperature SCH - schedule SDT - saturated discharge temperature ...
A SORIT valve is an EPR valve or ORIT (Open on Rise of Inlet Pressure) valve that also includes a solenoid stop. The purpose of the solenoid stop is to prevent the defrost gas from entering the suction line and overheating/overloading the compressors when the defrost solenoid opens and ba...
The liquid line and suction line remain dedicated to those tasks. So, the dual gas line will be a discharge line in this mode. It accomplishes this by leaving the dual gas pipe four-way valve de-energized. Outdoor heat exchanger control is determined by the load. Heating –During the ...
Solenoid Valves Sight Glasses Reversing Valve Line Tap Valve Thermal Expansion Electric valve Ball Valve Shut-off Valve Split A/C Valve Cut-off Valve Check Valve Orifice of Expansion Valve Brass Valve Ventilation,Fitting,Tape Pipe Copper Tube ...