Please connect the BNC connector to the Control Pilot and Protective Earth. An additional BNC-to-BananaPlug cable (Art.-No. 05210) can be ordered at Vector. For pin assignment see the VH5110(A) User Manual.BNC cable Please make sure, that the connection to CP and PE is as short as ...
Please connect the BNC connector to the Control Pilot and Protective Earth. An additional BNC-to-BananaPlug cable (Art.-No. 05210) can be ordered at Vector. For pin assignment see the VH5110(A) User Manual.BNC cable Please make sure, that the connection to CP and PE is as short as ...
1). We should put passive return loss network as close to the device as possible. 2). It would be best to have shortest distance between BNC connector and the device. 3). Please rotate DS30EA101 90 degrees counter clock wise. 4). Ple...
This serves to move any nonlinearity into a higher frequency region, outside the intended range of the probe, without causing severe overshoot. Rcomp and Ccomp2 represent the HF tuning components of the probe. This circuit is often on a PCB in a screened case right at the BNC connector to...
Prodigit also prepare the optional fixture Model 9951(P/N : 65233005), cost US$10.00 /pc, which is shown in figure 11 for PC power supply, so that the user immediately connect the power supply to the 4030 Figure 11:9951 PC Fixture with SMB connector 3. Conclusion : 3.1. ...
Connect anotherBack-pinning Probeto theblack plugon theBNC test leadand probe it into the 'FEN' terminal on the DLC Socket as shown inFigure 1. Using a suitable piece of insulated wire, connect one end to the DLC socket into the 'TEN' terminal and connect the other end to the 'GND'...
control and monitoring system with a multi-core processor, real-time operating system, programmable FPGA, and compatibility with all C Series modules from NI and 3rd party companies. CompactRIO lets domain experts build embedded I/O controllers and monitoring systems to help them solve their ...
Additionally, several sensors have high bandwidth capability and BNC connectivity options for quick connection to BNC measurement modules such as the NI 9223, NI 9222, and NI 9215. Figure 9: Verivolt has a variety of sensors with BNC connectivity that can connect directly to any NI module with...
Step 3: This is optional, but I put on a strain relief boot, which also helps to color-code my cables.Step 4: Untwist the individual wires, then rearrange them in the T568A or T568B standard.Step 5: Insert the wires into the Pass-Thru™ connector and in the crimper. Before ...
Synchronization between chassis can refers to a variety of different setups including: Using the PXI(e)'s External BNC Connector to output a clock. Aligning 2 data sets from different chassis together into 1 file. DAQ on two chassis begin at the same time by sharing triggers. Sharing refer...