1.1If user hits this issue with snapshot/clone operators, need to check the pvc status first.In most backup/restore scenarios, the clone action most probably cause the capacity runs out. If there are pending pvcs ,user need to delete them first. That is because the clone operation will kee...
【答案】:showframe-relaypvcandshowframe-relaymap
From the events, the PVC and 1 pod have been created. 1.1.1.3 PVC Before starting the containers of a pod, k8s needs to make sure the required PVs are bound to the PVCs. Checking the PVC's status: Pending Describing the PVC shows the Error above 1.1.2 Understand the erro...
If you are not sure whether the default configuration has been modified, log in to the router and run the display workmode wlan command to check its working mode. <Huawei> display workmode wlan Wlan Current WorkMode = ac Wlan Config WorkMode = ac //ac indicates the AC mode, and...
After the AC allows the AP to join, the AP state changes from Join to Configure and sends a Configuration Status Request message to the AC, requesting the AC to deliver the initialization configuration. Configure -> Data check After the AC delivers the initialization configuration, the AP state...
$ oc delete pvc db-noobaa-db-0 Delete the backingstores\bucket-class. Raw $ oc delete bucketclasses.noobaa.io --all $ oc delete backingstores.noobaa.io --all You might sometimes need to remove finaliziers for backing-store\bucket-class for the deletion to complete. Check if thats waiting...
Edit the spec.resources.requests.storage field of the corresponding PVC to expand the storage size declared by the PVC from 5Gi to 20Gi. # kubectl patch pvc html-nginx-lvm-0 -p '{"spec":{"resources":{"requests":{"storage":"20Gi"}}}' Check PVC/PV status: # kubectl get pvc NAME...
Notes:If the Virtual Circuit is incorrect, there will be no options. You can go to Status page to check which PVC you are using. Usually, there are IP parameters behind the correct PVC. Step 4: Add five rules like the picture below: ...
This PVC assumes that you used the default storage class names when you deployed OpenShift Data Foundation. Check the status of the PVC to make sure that it is successfully bound. Tiny File Manager There are supporting manifests in themanifestsfolder for deploying a PHP-based file manager prog...
In the first section, the file declares thelocal-storagestorage class. The second section defines thejenkins-pvpersistent volume, and the third creates a persistent volume claimjenkins-pvcthat binds to thejenkins-pvvolume. Thevaluesitem in thenodeAffinitysection should provide the name of the node...