MP35-08 HEAD-TO-HEAD ENERGY TRANSMISSION OF THE SUPER-PULSE THULIUM FIBER LASER VERSUS HOLMIUM LASER IN MULTIPLE FIBER SIZES AND SETTINGS.doi:10.1097/JU.0000000000003269.08Morgan, KalonKatta, NiteshAfyouni, Andrew S.Rojhani, AllenZarandi, Sina S....
The Nb2C solution was first prepared using the liquid exfoliation technique, and then deposited onto a microfiber for integration into the laser cavity. Stable mode-locking operation was observed in both laser cavities, where the center wavelengths of the laser were recorded at 1944 nm for the ...
Sixty single-rooted human teeth were randomly assigned to 1 of 3 groups according to laser power settings: 0.50, 0.75, and 1.00 W. Each tooth in each power group was subjected to lasing using fiber sizes of 140, 245, 355, and 410 μm. The dependent variables in these analyses included:...
Purpose: The purpose of this study was to evaluate the popcorn technique using a wide range of holmium laser settings and fiber sizes in a systematic in vitro assessment.Emiliani, EstebanTalso, MicheleCho, Sung-YongBaghdadi, MohammedMahmoud, SadamPinheiro, HugoTraxer, Olivier...
Urethrocystoscopy was performed using 30掳 cystoscope in lithotomy position under spinal anesthesia, followed by transurethral lithotripsy of prostatic calculi using a 550渭m laser fiber. Stone fragments were disintegrated using 100W laser generators (VersaPulse PowerSuite 100W, LUMENIS Surgical, CA). ...
METHODS Fibers were tested in small (150 - 300 micron) and medium (365 micron) core sizes. All fibers were evaluated for flexibility, true diameter, connector temperature, and failure threshold. Flexibility was measure by maximally deflecting a Stryker U-500 ureteroscopy with the fiber in the ...
for Er:YAG and 22 ± 6 for Ho:YAG (low hydroxy silica fiber) versus 5 ± 1 for Ho:YAG (sapphire fiber, p = 0.001). When fragmentation was normalized for incident laser fluence given different optical fiber sizes, mean fragmentation efficiency was 53.6 ± 38.7 g-μm. 2/J. for Er:...
Effect of power settings versus temperature change at the root surface when using multiple fiber sizes with a Hol- mium YAG laser while enlarging a root canal. J Endod 1998;24:802- 6.Cohen BI, Deutsch AS, Musikant BL, Pagnillo MK (1998) Effect of power settings versus temperature change ...
Nonetheless, between several surgical treatment modalities, transurethral holmium laser enucleation of the prostate (HoLEP) has emerged as a distinctive technique that can be applied to prostates of all sizes [2,3,4]. Compared to standard TURP, HoLEP offers better hemostasis, shorter catheterization...
across the stone surface (vfiber) and fiber standoff distance (SD) on dusting efficiency during short pulse holmium (Ho): YAG laser lithotripsy (LL), pre-soaked BegoStone samples were treated in water using 0.2 J/20 Hz at SD of 0.10~0.50 mm with vfiber in the range of 0~10 mm/s....