The EDS spectral imaging of a single NP with a spatial resolution below 10 nm has become possible. This is demonstrated by means of various examples of nanostructures. Advanced data processing of T-SEM/EDS results sets the stage for the automated classification of NPs by feature analysis. This...
Nano-probing system is SEM-based probing system optimized for electrical characterization and Electron Beam Absorbed Current (EBAC) analysis of semiconductor devices. High resolution SEM with high-brightness FE electron source enables intuitive operation and precise control of the probes. ...
High resolution multispectral spatial light modulators based on tunable Fabry-Perot nanocavitiesShampy Mansha, Parikshit Moitra, Xuewu Xu, Tobias W. W. Mass, Rasna Maruthiyodan Veetil, Xinan Liang, Shi-Qiang Li, Ramón Paniagua-Domínguez & Arseniy I. Kuznetsov ...
EGNITE microelectrodes can record neural signals with high fidelity and high spatial resolution, exhibiting high SNR (>10 dB) for local field potential recordings. MUA and single-unit activity (SUA) was also recorded with high SNR, and a proof-of-concept chronic intracortical experiment showed...
牛津仪器扫描电镜SEM专用颗粒物分析系统—适用于EBSDandEDSCharacterisationofhighentropyalloys参数规格?配套的耗材试剂? 牛津仪器扫描电镜SEM专用颗粒物分析系统—适用于EBSDandEDSCharacterisationofhighentropyalloys操作规程?使用注意事项? 牛津仪器扫描电镜SEM专用颗粒物分析系统—适用于EBSDandEDSCharacterisationofhighentropyallo...
resolution chemical analysis. By forming ananometersize electron probe, as small as 0.2nm, TEM is unique in identifying and quantifying the chemical and electronic structures of individual nanoparticles using electron energy-loss spectroscopy (EELS) andEDS. This is the high-spatial resolution ...
Pressure sensing array High resolution Wide pressure range Low crosstalk Foot-arch diagnosis 1. Introduction The continuous advancement of human–computer interaction (HCI) has resulted in significant development in the field of wearable devices for real-time data acquisition and effective medical diagnosis...
(FE-SEM) operating at 10 kV. Energy-dispersive X-ray spectroscopy (EDS) and elemental mapping were acquired with a high-resolution Zeiss Gemini500 thermal FE-SEM at 6 kV accelerating voltage. Surface hydrophobicity was indicated by water contact angles measured with a DSA100 Drop Shape Analysis...
(SEM; JSM-7600F) at an acceleration voltage of 15 kV. Elemental mapping was determined by an energy-dispersive X-ray spectroscopy (EDS, INCA X-Act). The high-resolution transmission electron microscope (HRTEM, JEM-2100 UHR) and selected area electron diffraction (SAED) images were acquired ...
SEM image of single waveguides with a designed width of 200 nm (Fig.1b). The fabricated waveguides exhibit a smooth surface topography, as seen in the magnified SEM image of the crossed waveguides in Fig.1c. Additionally, the linewidth and the cross resolution of the waveguides at the ...