A portable high-power microscope magnification lens structure, mainly comprises: a main body, a high-power lens being disposed on a middle part thereof which is passed through, an adhesive portion being disposed on a rear edge of the main body, LED lamps used for light compensating illumination...
Buyers Guide: What to Look for in a Microscope Power (Compound vs. Stereo Microscopes) Magnification Strength (Monocular vs. Binocular) Lenses (Objective Lens and Eyepiece Combination) DIN Compatible Objective Lenses Achromatic Objective Lenses Illumination Portability Slide Decks and Mechanical Stage Ergon...
The proximity approach is used, eliminating the need for projective microscope objectives for demagnification. A commonly used positive photoresist, AZ MiR 703, is used for a test. After post-exposure development in FHD-5 for 60 s, circular patterns emerge on the photoresist film. Figure 4b ...
We used a spacing of ∼10 μμm between the carrier and receiver as was judged from observation in an optical microscope (Figure 3a; height control ∼1 μμm). A fairly narrow fabrication window of fluence 5–6 J/cm22/pulse exists for LIFT for the most uniform particles. When the ...
640X Monocular Student Biological Microscope for Beginners and Advanced User(BM-42) Y Y***e 2020年4月27日 我喜欢这个产品来帮助我检查耳朵和清洁耳朵。 根据 英语 翻译而来显示原文 供应商回复: 谢谢你的喜欢。我们会尽力做得更好 根据 英语 翻译而来显示原文 1234...15 供应商详情 ...
To test the system, we initially employed the 100× objective lens and 1.5× microscope magnification dial and captured images of various static optical targets with a 1-ms exposure time, which yields a pixel size of 1 µm and a 20 µm × 40 µm FOV. As shown, the sy...
The surface and microstructure of the measured high-protein bars were examined using a polarising optical microscope Eclipse E600Pol (Nikon, Tokyo, Japan). The bars samples with an approximate area of one square centimeter were observed directly at the magnifications of ×40, ×100, ×200 and ...
This is mainly due to the resolving power of the microscope itself. Furthermore, in the case of the PE crystal, 0.37 nm (200) and 0.41 nm (110) fringes were resolved with a conventional TEM at room temperature.130–132 These values greatly exceed the dLD value for PE. It ...
magnificationinstrumental magnificationtable magniferEOC microscope tool TMulti-channels Motion Controller Y200MC-4 4 Channels Motion Controller for microscopesecond-hand robotic total station for surveying CX-52 price of total station construction surveying instrumentHospital use Ophthalmic Equipment Auto Ref/...
SEM images were taken by an FEI Magellan 400 XHR scanning electron microscope at an acceleration voltage of 5 kV. The elemental mapping results were analyzed by an energy-dispersive X-ray spectrometer (Bruker Quantax EBSD 400i system). Before SEM studies of cycled electrodes, batteries were disas...