GWPBPHEThis paper presents the heat transfer coefficients and the pressure drops measured during HFC404A vaporisation inside a commercial BPHE and the comparison of this data with previous measurements carried out during HC290 (Propane) and HC1270 (Propylene) vaporisation inside the same BPHE and ...
HFC404A vaporisation inside a Brazed Plate Heat Exchanger (BPHE): Comparison with the possible long-term low GWP substitutes HC290 (Propane) and HC1270 (Pr... HFC404A vaporisation inside a Brazed Plate Heat Exchanger (BPHE): Comparison with the possible long-term low GWP substitutes HC290 (...
Gwp 2000 MOQ 500PCS Class 2.2 Un No 3163 Water Content Less Than 0.001% Acidity Less Than 0.0001% Application Refrigerant Warranty 3years Transport Package Disposable Cylinder Specification 11.3kg/25lbs Trademark oem Origin China HS Code 3827630010 Pr...
GWP 0.29 Appearance Colorless & No turbid Odor Odourless Packing specification: Disposable steel cylinder 24lb/10.9kg; recoverable steel cylinder 400L, 800L, 926L; ISO-tank Uses: As refrigerant fluid replacing of R502 Packing, Payment and Delivery Packing 1 disposable cylinder,n...
GWPHFC404APropanePropyleneCondensationBPHEPropyleneEchangeur a plaques brasees (BPHE)This paper compares HFC404A and two possible hydrocarbon substitutes HC290 (propane) and HC1270 (propylene) in condensation inside a commercial brazed plate heat exchanger (BPHE) at saturation temperatures between 25 ...
HFC404A BOILING INSIDE A 4MM HORIZONTAL SMOOTH TUBE: COMPARISON WITH THE LONG-TERM LOW GWP SUBSTITUTES HC290 (PROPANE) AND HC1270 (PROPYLENE This paper presents the comparative analysis of HC290 (Propane), HC1270 (Propylene), and HFC404A during vaporisation inside a 4 mm smooth tube. The ...
This paper presents the comparative analysis of HFC404A and its low GWP substitutes HC290, and HC1270 in saturated vapour condensation inside a 4mm ID horizontal smooth tube. The experimental tests were carried out at 30, 35, and 40掳C of saturation temperatures, with refrigerant mass flux ...
[5] investigated this item considering six different solutions, however none of the substitutes proposed is able to overcome the most restrictive limit of the EU F-gas regulation (GWP < 150). Moreover all the substitutes proposed are HFC or HFC/HFO refrigerant mixtures with a large temperature...
GWPHFC404APropanePropyleneThis paper presents the comparative analysis of HC290 (Propane), HC1270 (Propylene), and HFC404A during vaporisation inside a 4 mm smooth tube. The experimental tests were carried out at three different saturation temperatures (5, 10, and 20 掳C) at increasing vapour...