Normative values for isometric muscle force measurements obtained with hand-held dynamometers. Physical therapy. 1996;76:248-59.Andrews AW, Thomas MW, Bohannon RW, et al. Normative values for isometric muscle force measurement obtained with hand-held dynamometers. PhysTher. 1996;76:248-25...
Normative Values for Isometric Muscle Force Measurements Obtained With Hand-held Dynamometers The extent of a patient's impairment can be established by comparing measurements of that patient's performance with normative values obtained from apparen... AA Williams,MW Thomas,RW Bohannon - 《Physical Th...
Exposure to hand-held vibrating tools may cause the hand-arm vibration syndrome (HAVS). The aim was to study the test-retest reliability of hand and muscle strength tests, and tests for the determination of thermal and vibration perception thresholds, which are used when investigating signs of ...
Hand strength has traditionally been quantified by measuring the hand's maximum ability to squeeze two parallel bars together. The grip dynamometer was created to measure this force and has changed little since the mid-1800's (Lanska, 2000). Isometric grip strength has been measured extensively ...
235 participants (aged 25.5 ± 9.5 for males and 26.4 ± 9.9 for females) completed a dual energy X-ray absorptiometry (DXA) scan to assess appendicular lean mass (ALM). Handgrip strength (HGS) was assessed using a handheld dynamometer. MQI was computed using four different model...
In SAGE, handgrip strength was measured in both the hands using a Smedley Hand Dynamometer (Scandidact Aps, Denmark). The measurement was taken in sitting position with hands dropped to the side. Respondents were asked to keep their upper arm against their body and bend their elbow to 90°...
Strength testing has involved isokinetic or hand-held dynamometry. Flexibility has usually been assessed by goniometry during maximal hip abduction. An ... C Hrysomallis - 《Journal of Strength & Conditioning Research the Research Journal of the Nsca》 被引量: 45发表: 2009年 Normative values of...
Handgrip strength measurement was carried out with the Jamar® dynamometer, which has been described as a valid measuring instrument [21,43]. The participant sits upright on a chair with back support and fixed armrests. Participants are asked to rest their forearms on the arms of the chai...
Recently, a novel reliable and valid protocol has been described for the measurement of eccentric strength of the external rotators of the shoulder, using a Hand Held Dynamometer (HHD). These muscles are prone to weakness in healthy as well as in injured overhead athletes. Objective assessment ...
However, up to date, no normative database exists regarding these values, when measured with a hand-held dynamometer. Therefore, the purpose of the study was to provide a normative database on isometric and eccentric rotator cuff (RC) strength values in a sample of overhead athletes, and to...