#define H_ERR_CAL_NCPF 8402 /* No calibration table found */ #define H_ERR_CAL_RECPF 8403 /* Error while reading calibration table description file */ #define H_ERR_CAL_LTMTH 8404 /* Minimum threshold while searching for ellipses */ #define H_ERR_CAL_FRCP 8405 /* Read error ...
我打印出了一张标定版,放在工作台下,然后相机用采集图像,采集了很多张,标定按钮一直按不了。请问是为什么?而且标定助手最下面有一行小字写着 “Halcon错误:No calibration table found” 是这个原因吗?这是什么意思? 喜欢0 最新打赏:0人 回复 xiechao 禁止发言 最后登录2018-12-08 发帖数101 金币153枚 贡献...
Previously,find_calib_objectonly returned the error 8402 ("No calibration table found") if the calibration plate with hexagonally arranged marks could not be found. Now, it can return the three additional errors 8397 ("Segmentation of the calibration marks failed"), 8398 ("Extraction of the mar...
The documentation did not state that the hand-eye calibration does not work with telecentric cameras. This problem has been fixed. Now, this behavior is documented in the reference manual entry ofcreate_calib_data. The reference manual entry ofcreate_dl_model_detectionlisted 'class_weights' as ...
Introduction to Camera Calibration Firstly, there is distortion in the lens, which means that the captured image does not match the actual image and causes deformation. Even industrial lenses have a distortion rate of a few thousandths. Secondly, no matter how high the mechanical structure accuracy...
#define H_ERR_CAL_NCPF 8402 /* No calibration table found */ #define H_ERR_CAL_RECPF 8403 /* Error while reading calibration table description file */ #define H_ERR_CAL_LTMTH 8404 /* Minimum threshold while searching for ellipses */ #define H_ERR_CAL_FRCP 8405 /* Read error ...
Now, the current tab gets closed, and if no other tab is open, CTRL + W closes the program window. The usability of the Window menu has been improved. The option 'Open Canvas' now has a dedicated icon. The usability of HDevelop has been improved. Now, it is possible to hide the ...
the number of pyramid levels was estimated too high. As a consequence, the estimated pyramid level was not settable by the user and matches may not have been found robustly. This problem has been fixed. Now, the maximum possible estimated pyramid level uses the same heuristic as a pyramid ...
'calibration_precisions' 'cast_precisions' 'conversion_supported' 'optimize_for_inference_params' 'precisions' Furthermore, the operator get_dl_device_param has been extended with the parameter 'settable_device_params', which returns a dictionary containing all device-specific parameters that ...
manual entry ofcreate_sheet_of_light_calib_objecthas been improved to mention that, if the parameters HeightMin and HeightMax were chosen such that the height difference between the truncated pyramid and the ramp was too small,calibrate_sheet_of_lightmight not have found the calibration object. ...