SetupInterconnect(EState *estate) { Interconnect_handle_t *h; h = allocate_Interconnect_handle(); Assert(InterconnectContext != NULL); oldContext = MemoryContextSwitchTo(InterconnectContext); if (Gp_Interconnect_type == Interconnect_TYPE_UDPIFC) SetupUDPIFCInterconnect(estate); #here udp初始化流程...
gp_interconnect_setup_timeout:在此时间内interconnect setup, 否则超时。当gp_interconnect_type设置为UDP时生效。默认2小时。 gp_interconnect_snd_queue_depth:设置发送方的发送窗口大小,增加该值会占用更多内存,设置为1-4较为合理。默认为2. 该值只有当gp_interconnect_type为UDPIFC时生效。 gp_interconnect_type...
Gp_Interconnect_type == Interconnect_TYPE_PROXY) SetupTCPInterconnect(estate);#here tcp & proxy else elog(ERROR, "unsupported expected Interconnect type"); MemoryContextSwitchTo(oldContext); h->Interconnect_context = estate->Interconnect_context; } SetupUDPIFCInterconnect_Internal初始化一些列相关结构,...
此参数越小,hash tables 越大,可提升 join 性能,相关参数还有 gp_interconnect_hash_multiplier、gp_interconnect_hash_multiplier、gp_interconnect_depth。 (21)gp_interconnect_setup_timeout 此参数在负载较大的集群中,应该设置较大的值。 (22)gp_interconnect_type 可选值为 TCP、UDP,用于设置连接协议。TCP 最...
gpconfig --show gp_interconnect_type 结果,查看参数语句像sql语句一样夯住了!杀掉: select * from pg_stat_activity where state ='active'; select pg_cancel_backend(32709); 直接修改参数:gpconfig -c gp_interconnect_type -v tcp 好的,又挂住了... 7.虽然...
1、由于gpload加载数据到gp数据库发生报错:ERROR|ERROR: Interconnect encountered a network error, please check your network (seg8 slice1 sdw2:40002 pid=26447)DETAIL: Failed to send packet (seq 1317) ...
gp_interconnect_hash_multiplier gp_interconnect_type gp_interconnect_queue_depth gp_max_packet_size gp_interconnect_snd_queue_depth 14.8.2 调度配置参数 gp_cached_segworkers_threshold gp_connections_per_thread gp_connections_per_thread gp_connections_per_thread gp_set_proc_affinity 14.8.3 故障操作参...
gp 数据库互联的性能与 Segment 上网卡的网络负载有关,所以 gp 服务器一般由一组多个网卡的硬件组成。为了达到最好性能,gp 建议为 Segment 机器上的每一个机器上的每一个主 Segment 配置一个千兆网卡,或者配置每台机器都有万兆网卡。 如果gp 数据库网络集群中有多个网络交换机,那么交换机之间均衡地分配子网较为...
gp_interconnect_type Sets the networking protocol usedforGreenplum Database interconnect traffic.Withthe TCP protocol, Greenplum Databasehasan upper limitof1000segment instances - less than thatifthe query workload involves complex, multi-slice queries. ...
只要删除/home/gpdata目录下的master/gpX/gpAdminLogs三个文件夹,然后重新执行即可。 数据导入与导出 一、数据导入 greenplum数据导入有五种方式: 1. insert:通过sql直接插入数据 2. copy:通过master节点加载,无法实现并行高效数据加载 copy tablename from '/home/../test.cvs' with delimiter ','; ...