composite materialsgraphitemicrowave materialsmicrowave spectrasilicon compoundssinteringwide band gap semiconductors/ SiC matrix structure-function compositespressureless sinteringmicrowave attenuation property
cellular and functional level. A combination of microscopy, gene and protein expression analysis, neurobehavioral assessments and pharmacological rescue in this model shows that placenta ALLO insufficiency leads to cerebellar
The identity and purity of the peptide–DNAs were confirmed by ESI-MS (ThermoScientific Q Exactive HF-X) and matrix-assisted laser desorption/ionization MS (AB Sciex 5800 MALDI-TOF/TOF). The peptide–DNAs were quantified by absorbance measurements at 260 nm, lyophilized in aliquots of 0....
3b)139. In lower strain regimes, the stretching of the elastomeric matrix increases the distance between conductive particles. As the strain increases, the conductive pathways break. The addition of PU-PEDOT:PSS conductive polymer ensures that during extreme stretching, some conductive pathways are ret...
This review summarizes the multifunctionalization and interdisciplinary applications of microwave-absorbing materials, including their use in infrared stealth, high-temperature resistance, anti-icing, human body protection, and the interdisciplinary linkage of microwave-absorbing materials with anti-tumor, ...
Frequency response function is defined as the Fourier transform of the time domain response divided by the Fourier transform of the time domain excitation input. Eqs. (2.1) and (2.2) can be written in matrix form as: (2.16)[M000]·{z¨V¨}+[c0−αC0]·{z˙V˙}+[Kα01/R]·{zV...
Knowing that pi(X) is normal when p(X|Mi) and p(Mi|ωi) are normal, we can simply calculate the expected vector and covariance matrix of X assuming ωi: (3.94)E{X|ωi}=∫Xpi(X)dX=∫∫Xp(X|Mi)p(Mi|ωi)dX dMi ...
this transfer function only reflects the frequency characteristics of the system and cannot be used for vibration calculations because both the system external force and the system displacement contain unknown quantities. And, due to matrix inversion, this method becomes inapplicable as the DOF of the...
However, two additional points needs to be considered using EDXS analysis of FIB-foils: (i) the common software used does not consider the analysis of a thin specimen such that the correction algorithms (see for example, Lorimer 1987) for the matrix effects related to the different excitation...
and sliced into 1-mm coronal sections using a brain matrix (RBM-4000C, ASI Instruments, Warren, MI). Using blunt 20-guage needles attached to 1 ml syringes for brain region microdissection [9,31,65,66,67], the dentate gyrus (DG) and CA1 region of the dorsal hippocampus (− 5.30...