Software switch Hardware switch Zone Virtual wire pair PRP handling in NAT mode with virtual wire pair Virtual switch support for FortiGate 300E series Failure detection for aggregate and redundant interfaces VLAN inside VXLAN Virtual wire pair with VXLAN QinQ Configure IPAM locally ...
On the primary FortiGate, configure the hardware switch: config system virtual-switch edit Hardware-SW set physical-switch sw0 config port edit port3 next edit port5 next end next edit Hardware-SW2 set physical-switch sw0 config port edit port1 next end next end ...
SFP+ER FN-TRAN-SFP+SR FN-TRAN-SFP+BD27 FN-TRAN-SFP+BD33 FN-CABLE-SFP+1 FN-CABLE-SFP+3 FN-CABLE-SFP+5 Description 18x GE RJ45 ports (including 1x MGMT port, 1x HA port, 16x switch ports), 8x GE SFP slots, 4x 10GE SFP+ slots, SP5 hardware accelerated, dual AC power supplies...
New Sealed R8N85A CX 6000 Series Switch 48G Class $1,133.00 Min. order: 1 unit Easy Return New Factory Sealed FG-81F FC-10-0081F-950-02-12 FortiGate-81F 1 Year Unified Threat Protection $1,099.00 Min. order: 1 unit Easy Return ...
(BLE) — Signed Firmware Hardware Switch — Included Transceivers 0 System Performance — Enterprise Traffic Mix IPS Throughput 2 2.6 Gbps NGFW Throughput 2, 4 1.6 Gbps Threat Protection Throughput 2, 5 1 Gbps System Performance and Capacity IPv4 Firewall Throughput (1518 / 512 / 64 byte, UDP...
Possible conflicts between software switch VLAN setting and its member interface VLAN setting. 641419 FG-40F LAN interfaces are down after upgrading to 6.2.4 (build 5632). 641708 FTLF8536P4BCV shows This transceiver is not certified by Fortinet, corrupt part number and serial number after HA ...
Software switch Hardware switch Zone Virtual Wire Pair Virtual switch support for FortiGate 300E series Failure detection for aggregate and redundant interfaces VLAN inside VXLAN Virtual Wire Pair with VXLAN QinQ Assign a subnet with the FortiIPAM service Configure a VRF ID on an inte...
(BLE) Signed Firmware Hardware Switch System Performance and Capacity IPv4 Firewall Throughput (1518 / 512 / 64 byte, UDP packets) IPv6 Firewall Throughput (1518 / 512 / 86 byte, UDP packets) Firewall Latency (64 byte, UDP) Firewall Throughput (Packet per Second) Concurrent Sessions (TCP...
(BLE) — Signed Firmware Hardware Switch — Included Transceivers 2x SFP (SX 1 GE) System Performance — Enterprise Traffic Mix IPS Throughput 2 12 Gbps NGFW Throughput 2, 4 10 Gbps Threat Protection Throughput 2, 5 9 Gbps System Performance and Capacity IPv4 Firewall Throughput (1518 / 512...
Software switch Hardware switch Zone Virtual wire pair PRP handling in NAT mode with virtual wire pair Virtual VLAN switch VXLAN General VXLAN configuration and topologies VLAN inside VXLAN Virtual wire pair with VXLAN VXLAN over IPsec tunnel with virtual ...