It can put out the fire in the cabin through manual operation and pneumatic releasing the HFC-227ea in the cylinder. 2.3.3气控施放阀 Pneumatic Releasing Valve 气控施放阀是一种气控快开阀,又叫选择阀,其工作原理为当控制气体推动所属的气缸活塞,带动曲柄动作,使转轴旋转,即主阀处于可开启状态,在...
Clean Agent Fire Tube fire detection tube Automatic fm200/hfc-277ea fire trace suppression system $4.20 - $6.00 Min. order: 1 meter High pressure water mist fire hose reel,fire hose reel price,fire hose reel cabinet $1.00 - $50.00
FM200 Fire Suppression System Maintenance Switch $10.00 - $28.00 Min. order: 1 unit Key resettable manual fire alarm pull station $5.00 - $9.00 Min. order: 1 piece Red Color Fire Alarm Pull Station Manual Call Point With Resettable Key ...
FM200FireExtinguishingSystem-Chrysler.doc SECTION 13905 - FM 200 FIRE EXTINGUISHING SYSTEM PT Modifications GENERAL 1.1 SUMMARY This Section includes FM 200 or Carbon Dioxide fire extinguishing systems for machine tools and auxiliary devices where straight oil coolants are utilized. Work Included by This...
Filling pressure::4.2 MPa;Extinguishing agent filling density::≤950kg/m3;System Power Supply::AC220V/DC24V/1A;Extinguishing agent release time::≤10s;System working environment temperature::-10℃~55℃;Storage bottle volume::40L, 70L, 90L, 120L,150L;Outp
Operation of a manual discharge station shall cause alarm and shutdown devices to operate the same as if the system had operated automatically and include two types.对于每个受保护区域,系统 均应能够通过手动释放按钮激活。手动释放按钮动作应和自动动 作一样,能够报警并关闭某些装置使系统动作,包括两种方式...
Operation Temperature 0-50°C Starting Mode Manual/Auto 2.Cabinet type The cabinet fire extinguishing device is also called a pipeless network fire extinguishing system and a prefabricated fire extinguishing system, and is composed of a fire extinguishing agent storage bot...
1.Automatic Operation : 24 VDC Electro-Magnetic Actuation Valve2.Remote Manual Operation : Remote Pull Station3.Local Manual Operation : Local Manual Actuation available on electric valve on PilotTank as well as Pneumatic valve on FM-200 Tank 11:Distnbution Piping12:Flange13:Dlscharge Pressure ...
2.1 The basic parameters of system Fire put out methods: Total flooding fire System startup mode: Automatic, manual, mechanical emergency operation Design temperature: -20 ° C ~55 ° C Discharging time of gas agent: Not more than 10s Voltage of system startup: D...
the fire extinguishing agent is released, and the fire is extinguished; if the duty officer discovers a fire, he can press the emergency start button outside the protective area door to implement the fire extinguishing operation ; There is also a manual button on the solenoid valve...