This supplement contains information necessary to ensure the accuracy of the above manual. Enter the corrections in the manual if either one of the following conditions exist:1. The revision letter stamped on the indicated PCA is equal to or higher than that given with each change.2. No revisi...
Model 787 ProcessMeter Calibration Manual May 1998 Rev. 3, 7/17 © 1998-2017 Fluke Corporation. All rights reserved. Specifications are subject to change without notification. All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke...
溫度規格(只限於 87 型) 47 14. 電流功能規格 48 15. 電容和二極體功能規格 49 16. 頻率計數器規格 49 17. 頻率計數器靈敏度和觸發電平 50 18. 端子的電氣特性 51 19. MIN MAX 記錄規格 52 iii 80 Series V 使用手冊 iv 圖目錄 圖 標題 頁碼 1. 顯示螢幕功能(87 型) 11 2. 測量交流和直流電壓...
FLUKE-87-V-EX产品配件 参考图片 制造商 / 说明 / 型号 / 仓库库存编号 PDF 操作 Fluke Insulated Test Lead; 600V (CAT IV), 1000V(CAT III); 10A; Red/Black; UL Listed 型号:TL224 仓库库存编号:70145561 搜索 Fluke Clamp, AC Current; 400A; CAT IV 600V, CATIII 1000 VAC; 750 MCM; 1.25...
Fluke Connect TM compatible TECHNICAL DATA SUPERIOR IMAGE QUALITY RESOLUTION 640 x 480 (307,200 pixels)SPATIAL RESOLUTION 0.93 mRad FIELD OF VIEW 34 °H x 24 °V Ti401 PRO, Ti480 PRO, TiX501 and TiX580 Infrared Cameras Provided by:www.atecorp.com (800)404-ATEC ®Rentals • Sales...
from 5.5 V to 13.5 V depending on the manufacturer.The output of the loop isola- tor is an electrically isolated mirror image of the input side current. The compliance voltage associated with the output is greatly reduced from that of the input side and ranges around 7.5 V. This ...
Ease of Use– do I have to read the manual to figure out basic operations? Probe Quality– do I have to spend more to replace junky probes? The Fluke 87V, which is the 5th edition of the 87-series meter, is as great as can be in each of these areas. It has all of the measurem...
87 mm 高度 32 mm 物理参数 重量 369 g 符合标准 RoHS标准 Non-Compliant REACH SVHC标准 No SVHC 产品概述 Fluke 787 ProcessMeter™ Fluke 787 ProcessMeter™ 组合回路校准器和数字万用表是坚固工具,用于故障诊断和校准电流回路应用。 精密 1000V 440mA 的数字万用表可测量交流和直流电压、交流和直流电流...
I have an older Fluke 87III and the diode test is not working. I get no beep, no change on the display.If i short the leads, the display updates to 0V, but again, no beep.The speaker works and beeps on continuity tests, so it's definitely something specific to the diode test.Any...
The manual for the original Fluke 87 (and other models) is only a google search away:https://assets.fluke.com/manuals/87___umeng0800.pdfAs you can see from the specs, it's only 4000 counts, 0.1% accuracy on DC volts, etc. ie. It's a good meter but it's definitely not an 87V...