The 5520A-PQ option can be ordered factory installed with a new calibrator or added to your existing 5520A at a local Fluke Service Center.Three power quality modes are packed with features The three power quality waveform modes in the 5520A-PQ include Composite Harmonic, Flicker Simulation, ...
The SC1100 enables the enhanced performance 5520A to calibrate all of your oscillosocpes up to 1.1 GHz with rise times to 300 ps – even 125 ps with the 5800A/TDP tunnel diode pulser option.
Request a quote Product overview Specifications Models Reviews + Q&A Manuals + resources Compatible accessories Product overview: 52120A Transconductance Amplifier Priority Gold Instrument CarePlan Make sure to ask your account manager about the Fluke Calibration Priority Gold CarePlan A Fluke Calibration ...
5520A-SC1100 | Opción de calibración de osciloscopios de 1,1 GHz El modelo SC1100 permite al dispositivo 5520A de rendimiento optimizado calibrar todos los osciloscopios de hasta 1,1 GHz con tiempos de subida de 300 ps, incluso de 125 ps con la opción de generador de impulsos ...
altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not ...
1 360 AC Leakage Current Clamp Meter Calibration Information Introduction This document provides the following information for the 360 AC Leakage Current Clamp Meter (hereafter referred to as the Meter or UUT):• Safety information • Symbols • Specifications • Maintenance • Performance Tests...
Fluke 电子计量仪及校准解决方案说明书
5520,Fluke5520AMultiproductCalibrator M5520 5700,Fluke5700AMultifunctionCalibrator MMFC 5720,Fluke5720AMultifunctionCalibrator M5720 5800,Fluke5800AOscilloscopeCalibrator M5800 5820,Fluke5820AOscilloscopeCalibrator M5820 P525PressureCalibrationusingFluke525A P700PressureCalibrationusingFluke525Aor5520A 9000,Wavetek/...
eachmeterfunctionagainsttheMeter’sspecifications.IftheMeterfailsanypartofthetest,calibration adjustmentand/orrepairisindicated. Intheperformancetests,theMeterisreferredtoastheunitundertest(UUT). Table1.RequiredEquipment EquipmentRecommendedModel ACCalibratorFluke5520A DigitalMultimeter(DMM)AnyFlukemodel 50-TurnCurr...
This version applies to all 5540A/5550A and 5560A Calibrators Specifications are now available within scope functions Corrected issues with phase adjustment in AC_POWER and ACV_ACV functions Corrected issues with remote REFOUT? command to more closely match 5520A operation ...