Flash Point testing is a critical evaluation method used in the field of fuels to assess their flammability and safety characteristics. It is a crucial parameter in understanding how easily a fuel can ignite and subsequently pose risks during storage, transportation, and handling. During Flash Point...
The effect of pressure on the flash point (FP) of various fuels (methanol, ethanol, acetone, ethyl acetate, n-hexane, n-octane, benzene, toluene) and their binary mixtures (ethanol-acetone, ethanol-n-octane, methanol-hexane) has been quantified. It has been found that the FP significantly...
译文示例:Equipment which uses liquid fuel may be operated only with fuels whose flash point is above 55 °C. ↔ En las instalaciones que funcionen con combustible líquido sólo podrán utilizarse combustibles con punto de inflamación inferior a 55 °C. flash fuel + 加 英文-西班牙文字...
Flash point of diesel fuels is measured according to ASTM D 93—Flash-Point by Pensky-Martens Closed Cup Tester. The sample is stirred and heated at a slow, constant rate in a closed cup. At specific temperature intervals (1 or 2 °C), the cup is opened and an ignition source is move...
网页设计者使用 Flash 创作出既漂亮又可改变尺寸的导航界面以及其他奇特的效果。 bio fuels 生物燃料 flash o lens 闪光透镜 flash over 飞弧 flash lamp n. 〈摄〉闪光灯,闪光泡 flash news n. 大新闻 flash point 【医】 闪(燃)点 flash forward n. 提前叙述未来事件 high flash 高闪点 ...
lit. flash point— 闪光点 也可见: 闪名 flash名— 闪存名 · 快闪名 · 忽然的一阵名 · 闪耀名 · 突发名 · 闪光名 · 闪光灯名 flash— 闪现 · 掣电 · 焕发 · 忽闪 · 闪熠 · 熠 · 闪灼 flash动— 瞥一眼动 · 突然闪过脑海动 ...
12. In experiments, it is found that the extinguishing mechanisms are always different with obviously different flash point of liquid fuels. 实验中发现,当液体燃料的闪点相差较大时,其灭火机理往往不尽相同。 youdao 13. The flash point must be high, the display must be small, satisfies the fire ...
Flash point The flash point of a flammable liquid is the lowest temperature at which it can form an ignitable mixture in air. At this temperature the vapor may
The methodology assumes that the flash point of kerosene fuels can be expressed as a function of elemental composition and several structural parameters. The proposed correlations have determination coefficients of 0.910 and 0.977. Also, the first model has root mean square deviation (RMSD) and the...
A method is described for the determination of the flash point of fuel oils, lube oils, suspensions of solids, liquids that tend to form a surface film under the testing conditions, and other liquids. Using a Pensky-Martens closed-cup tester, the sample is heated at a slow, constant rate...