Fire Alarm System Emergency Door Release Manual Call Point With Reset Key Technical Data: Item No. MTCP01 Operation voltage 24VDC Max. Current 1A AT 24VDC Contact Resistance ≤0.2ohm Working conditions Temperature: range: -10ºC~+50ºC Max. relative humid...
Main Voltage:Zone 24V or 12V;Operating current:monitoring status≤20uA, alarm status≤15mA;Application:For indoor use only;Wiring:The promise of two bus system(Zone +, Zone -);Protection class:IP30;temperature range:-5 to 40°C (23~104°F);Humidity:5 to
Supplier Homepage Products Fire Alarm System Explosion-proof Fire Alarm System Explosive Proof Fire Hydrant Button with Reset Key Hot Searches Fire Alarm Fire System Door Alarm Fire Security Disinfection Station Explosion Proof Camera Police Station Fire Alarm Box Entrance...
Easy to Use: The resettable key feature allows for quick and easy reset of the manual call point, minimizing downtime and ensuring seamless operation. Flexible Power Options: The device is compatible with both 24V and 12V main voltage systems, providing flexibility in system integration. Indoor Ap...
1.Checking of physical appearance of the fire alarm devices 2.Smoke Detectors should be cleaned & tested for sensitivity levels (addressable type) 3.Fire alarm control panel should be tested for all alarm, trouble, supervisory, reset & silence function ...
that can be normally open, normally closed or a combination of both. Either a key or tool (depending on station selected) is required to reset mechanism. Where a manual station is installed on a circuit that also includes smoke detectors, a resistor can be added in series with the alarm ...
Alarm Operation: When an alarm occurs, the top line of the display shows FIRE ALARM . This display overrides any other system display. The second line of the display shows the point number in alarm, alternating with the programmed description for the affected point. If more than one alarm ...
The alarm state is maintained until a reset is successfully performed. The reset logic, upon a reset command, resets the alarm state if the measured parameter is below a predetermined reset threshold, and inhibits resetting of the alarm state if the measured parameter is above the predetermined ...
Resetable Conventional Fire Manual Call Point with Key(ES-9002-2) General Description Features and Benefits Compatible with all the conventional fire alarm control panel Can be reset by key without use a new glass 470 Ohm resistance Easy surface mounting Base included...
Product Name AS-MCP01EX Fire Alarm Explosion Proof Manual Call Point Color Red Power Supply 24VDC Contact Capacity Normally open 0.5A LED Indicator 1 Green (working) LED Indicator 2 Red (alarm) Accessory Reset key Explosion Proof Mark Exd (ib) II CT6 Atmospheric Pressure 80~110...