The Audio Notification System (ANS) is a self-contained amplifier, tone generator, digital message repeater, and supervisory interface. It is designed for use with a UL Listed fire alarm control panel (FACP) to provide a listed voice evacuation alarm system. See Table 1 for a list of ANS ...
a super-sensitive central sensor, a smoke transport fan, electronics to interface with a FACU for alarm and trouble conditions, and a power supply. These are typically more sensitive than spot-type smoke detectors and are used in high-value, high-risk scenarios (e.g., data centers, clean...
•CO Alarm (blue) illuminates when at least one CO alarm event exists.•SUPERVISORY (yellow) illuminates when at least one supervi-sory event exists (i.e., sprinkler valve off normal, low pressure,fire pump running, guard’s tour, etc.).•TROUBLE (yellow) illuminates when at least ...
SR-P01-16 16 zones conventional fire alarm control panel The SR-P01 Series Conventional Fire Alarm Control Panel is a 24 volt, four to sixteen-zone, Class B, Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and future ULC codes, the highly...
SR-P01-16 16 zones conventional fire alarm control panel The SR-P01 Series Conventional Fire Alarm Control Panel is a 24 volt, four to sixteen-zone, Class B, Conventional Fire Alarm Control Panel. Designed exclusively to meet the latest market requirements and future ULC codes...
FIRE ALARM FACILITY TROUBLE SENSOR DETECTORKOBAYASHI RIYOUSAKU
A fire alarm system has three possible states: normal, alarm and trouble. The current state is displayed permanently by the control panel. Fire alarm systems are in the normal state most of the time, when no fires or performance issues have been detected. The alarm state indicates that a fi...
This allows the control panel to continually process the information to determine the status (alarm, trouble, maintenance or normal) of each detector. Each detector responds to an SLC address that is set in the detector head using built-in rotary decimal switches with the ability to select up ...
aAlarm signals should be sent to the 24-hour attended alarm control panel when the fire pump is in trouble, turned off, or set at manual start. In addition, anti-corrosion solutions should be applied to all cast iron pipes. 应该寄发报警信号到24小时出席的警报控制板,当消防泵在麻烦时,被关...
All status changes must clearly indicate that the information is an Alarm (ALM), Supervisory (SUP), Trouble (TBL), or Monitor (MON). QS4 Technical Reference Manual 1.11 Product description Interpretation of screen displays HH:MM:SS MM/DD System Normal Project Name This is what the...