However, it also means the binaries need to be decompressed each time they are run, which can have a significant overhead. If that is an issue, you can either stick to the "classic" individual binaries or you can decompress the universal binary, e.g.: upx -d dwarfs-universal-0.7.0-...
The invoked script defines automatic service deployment upon device startup. To configure more service functions for ZTP, edit the Python script by referring to the following file example and "Writing an OPS API-based Script" in CLI Configuration Guide > System Management Configuration....
public static readonly System.Xml.Linq.XName FileBinding; Field Value XName Remarks As an XML attribute, it: is contained in the following XML elements: DataBinding. corresponds to the following strongly-typed properties: DataBinding.FileBinding. Applies to 產品版本 DocumentFormat.OpenXml 2.15.0,...
6379 为 redis-master 的端口,2 为最小投票数(因为有 3 台 Sentinel 所以可以设置成 2) sentinel monitor mymaster 192.168.147.132 6379 2 sentinel down-after-milliseconds mymaster 30000 sentinel parallel-syncs mymaster 1 sentinel failover-timeout mymaster 180000 sentinel deny-scripts-reconfig yes...
Filename = name() Terms = [term()] Reason = posix() | badarg | terminated | system_limit | {Line :: integer(), Mod :: module(), Term :: term()}Reads Erlang terms, separated by '.', from Filename. Returns one of the following: {ok, Terms} The file was successfully read....
make OverridDemo=ThisIsFromOutShell 绑定目标的变量 Makefile中的变量一般是全局变量。也就是说定义之后在Makefile的任意位置都可以使用。但也可以将变量指定在某个目标的范围内,这样这个变量就只能在这个目标对应的规则里面保用 语法 target …:variable-assignmenttarget …:prerequisitesrecipes ...
numSuccJobId (%d) The number of jobs that were successful during this remote control operation. succJobIdArray (%d) Contains IDs for all the jobs that were successful during this remote control operation. numFailJobId (%d) The number of jobs which failed during this remote control session. ...
654 + VAL_ 1057 STATUS20 5 "Over current" 4 "Bad fuse" 3 "Bad relay" 2 "No load" 1 "On" 0 "Off" ; 655 + VAL_ 1057 STATUS19 5 "Over current" 4 "Bad fuse" 3 "Bad relay" 2 "No load" 1 "On" 0 "Off" ; 656 + VAL_ 1057 STATUS18 5 "Over current" 4 "Bad fuse...
- Normal operating power consumption does not (see "DC specifications" on page 30 for current ecxocneseudmtphteiosnumspoefcIiCfiCcaCtoiorensm).ax and ICC USB max - The I/O power supplies VDDIO1 should never be tVuDrDnIeOd2 aonffdf...
("Set screen length to un limit success.", LOG_INFO_TYPE) return True @cli_operation_x def set_con_password(ops_obj=None, handle=None): cli_list = ["return", "system", "user-interface con 0", "authentication-mode password", f"set authentication password cipher {CON_PASSWORD}"] ...