This paper discussed the fault current limiting requirements and proposed a calculation method to determine the required dc reactor value, for the purpose of the converter continuous operation during dc faults. On this basis, the bridge-type fault current limiter (FCL) was proposed for using in ...
Short circuit current limiter in as network of the current limiter, which can meet the requirements set for locations of bus tie, feeder, as well as the main transformer in the distribution ... Wu,Zhao-lin,Chen,... - 《Journal of Zhejiang University Science A》 被引量: 37发表: 2001年...
Fault current limiterFault ride throughProtection coordinationFault ride through (FRT) requirements are imposed by grid codes in order to prevent from the loss of power generation due to the voltage drop caused by grid faults. To keep the wind turbine connected to the network the protection system...
Optimum fault current limiter placement with search space reduction technique A fault occurring in power networks normally results in a large short-circuit current flow in the system, which may exceed the rating of existing circuit b... Teng, J.-H,Lu, C.-N - 《Iet Generation Transmission &...
The utility requirements for a fault current limiter IEEE Transactions on Power Delivery (April 1992) R.K. Smith et al. Solid state distribution current limiter and circuit breaker: application requirements and control strategies IEEE Transactions on Power Delivery (July 1993) There are more reference...
According to the recent grid codes, wind turbine systems (WTSs) are required to stay connected to the grid during grid faults and provide reactive power to support the grid. Therefore, this paper proposes a noncontrolled fault current limiter (NCFCL) with reactive power support...
Fault Current Limiter Market by Type (Superconducting & Non-superconducting), by Voltage Range (High, Medium & Low), by End-Users (Power Stations, Oil & Gas, Automotive, Steel & Aluminum, Paper Mills & Chemicals) and by Region - Global Forecast to 2020 ...
Series Resonance Fault Current Limiter (SRFCL) with MOV for LVRT Enhancement in DFIG-Based Wind Farms—To reduce the negative effects of wind farms connection on power system stability, many countries have elaborated grid code requirements. Low-voltage ride through (LVRT) capability is the ......
Finite-element modelling of YBCO fault current limiter with temperature dependent parameters L. Antognazza et al., "Finite-element modelling of YBCO fault current limiter with temperature dependent parameters," Superconductor Science & Technology, ... J Duron,F Grilli,L Antognazza,... - 《Superco...
A fault current limiter (FCL) is an outstanding apparatus which the impedance does not appear when no fault occurs, but the impedance appears only when a fault occurs in a power system. The operation of the FCL causes the effective reduction of the fault current. Although there are various ...