9:‘Confirm new parameter signature?’→ 选择‘YES’ 10:应用设置数据,‘DCS’界面 →‘APPLY’→ 输入‘Code number’→ 四个‘1’11:设置内容核实 → 选择‘OK’ 12:重启 →‘CYCLE POWER’→ 完成配置3. Dual Check Safety 功能检测 通过TP 示教器查看设置安全区域、机器人本体、工具等 DCS 状态,以及...
5、点击PREV返回DCS界面,选择4Safe 1/0 device如下图所示 6、进入Safe I/O device界面,选择1Safe 1/O process,按F4选择I/O connect, 如下图所示: 7、选择2 SFDO Pulse check,按F4选择ENABLE (PL e) 如下图所示: 9、输入Code number (master)1111,进入Verify界面,如下图所示: 10、按F3,选择ALL,进入...
点击PREV返回DCS界面,按F2应用所修改的设置,如下图所示:输入Codenumber(master):1111,进入Verify界面,如下图所示:按F3,选择ALL,进入Verify界面,如下图所示:按F4OK,应用完成,自动返回DCS界面,如下图所示:点击MENU选择5I/O,然后选择EtherNet/IP,如下图所示:进入EtherNet/IP...
按键MENU—NEXT PAGE—SYSTEM—DCS—PROFINET Safety(针对不同的工业总线,此处会有相应通讯方式的显示)—F3 DETAIL—第1项改为BYPASS; 按PREV键,返回上层界面,按F2APPLY ,在Code number(master)中输入1111; 在弹出的界面中,点击OK,等待几秒后会返回DCS主界面,之后重新启动机器人,完毕...
DCS (Dual Check Safety), limit switches and hardstops also limit travel by the major axes. EMERGENCY STOP limit switches and photoelectric eyes might be part of your system. Limit switches, located on the entrance/exit doors of each booth, will EMERGENCY STOP all equipment in the booth...
FANUC数控系统31i-B PMC编程说明书(英文版).pdf,FANUC Series 30+-MODEL B FANUC Series 31+-MODEL B FANUC Series 32+-MODEL B FANUC Series 35+-MODEL B PMC PMC PROGRAMMING MANUAL B-64513EN/01 • No part of this manual may be reproduced in any form. • All
There are two levels of DCS Code numbers Master and Local. The Local are...? Base, Position/Speed Check, and I/O Connect If updated in Non-DCS menus, what does not need to be applied to the DCS Parameter? Hint: Consider ALL possible setup situations Axis limits The maximum number of...
CheckSafety(DCS) ¡Integrationofmotioncontrolandsafety ¡ConformitywithInternationalSafetyStandard“FunctionalSafety” ISO13849-1 3State-of-the-Art High-Speed,High-Rel iabi l ity Hardware Ultra-Compact,Reduced wiring,High-Rel iabi l ity
PMC Function Library for DCSPMC (PMC_DCS.FLL) has been added. The symbol data has been able to be copied as the symbol of an automatic assignment when copying nets of ladder in PMC model of “Extended Symbol” or “Multi Language Comment”. ...
- DCSPMC function has been supported. (Machine signal simulator is not available for DCSPMC.) Ver 21.10 (2021.06.11) - The following problem is corrected. + When files in memorycard are displayed at PMC data I/O screen, wrong file information is displayed. (FS0i-F, FS0i-F Plus) Ver...