If so, go to step 2. If not, enable the dual-link backup function. Run the display wlan ac protect command on the active AC, and check whether the dual-link backup function is enabled. If not, run the ac protect
After the command is run, restart the switches to make the configuration take effect. The interface Stack-Port is down. The protocol status of a logical stack port is Down. Run the display interface brief command to check whether the physical status of a logical stack port is Down. If so...
wlan0: interface state UNINITIALIZED->ENABLED wlan0: AP-ENABLED /modules # here i can't find the hotpot. even sometimes i will get some failure info when i run hostapd; brcmfmac: brcmf_sdio_bus_rxctl: resumed on timeout brcmfmac: brcmf_cfg80211_start_ap: SET SSID error (-110) ...
Hello, IMC101 has two UART ports, UART0 and UART1. By default, UART0 is used as the program port and UART1 is used as the user UART interface. The UART used for downloading does not have a specified baud rate. You can refer to the programming manual. Before downloading, the...
(wrapped by meson to set PATH, to set env) +[105/121] Generating parquet-glib/Parquet-1.0.typelib with a custom command (wrapped by meson to set PATH) +[106/121] Generating arrow-dataset-glib/ArrowDataset-1.0.typelib with a custom command (wrapped by meson to set PATH) +[107/121] ...
[INFO]Response: No - error: [XORG] (EE) /dev/dri/card0: failed to set DRM interface version 1.4: Permission denied [ 125.219682] [ERROR]Cannot access secondary GPU - error: [XORG] (EE) /dev/dri/card0: failed to set DRM interface version 1.4: Permission denied [ 125.219688] [DEBUG]...
('connect',function(err){if(err){console.log('Error: ',err)}// If no error, then good to go...console.log('Hello world 2');executeStatementWaitFor();});connection.connect();functionexecuteStatementWaitFor(){request=newRequest("Waitfor Delay '00:01:00'...
Error: An error occurred while assigning a value to variable "Result": "Unable to find column Result in the result set.". Error: An error occurred while skipping data rows Error: Data conversion failed while converting column ERROR: Method not found: 'System.String Microsoft.SqlServer.VSTAHosti...
Server/router-side tcpdump of LAN interface eth1(20.00 KB, text/plain) 2012-03-01 04:53 UTC,Steven Noonanno flagsDetails in depth debug patch(6.15 KB, patch) 2012-03-02 21:06 UTC,Neil Hormanno flagsDetails|Diff better dmesg with extra printks(93.66 KB, application/octet-stream) ...
So, you can try to install net 4.6.1 as an administrator. If you will still get this error(Installation failed with error code: 0x00003712, "The component store has been corrupted.) when installing net 4.6.1 , You can try the ※DISM§ to help you solve the issue. ...