英文: If installing the water heater in a closed water system, install a relief valve or expansion tank in the cold water line as specified under Closed System/Thermal Expansion. 中文: 如果是在一个封闭的水系统中安装热水器,按照“关闭系统/热膨胀”中的规定,安装一个安全阀或膨胀罐。 更详细.....
PURPOSE: To obviate water supply pipe, etc., for an expansion tank on the side of a cold water circuit, by a method wherein an airtight expansion tank for cold water is connected to an air opentype expansion tank for hot water with a connecting pipe. ;CONSTITUTION: An airtight expansion ...
A water heater expansion tank is a small tank installed on the cold water supply line to a water heater. Its purpose is to help protect thewater heating system and plumbing from damage caused by thermal expansion. When water is heated, it expands, and the volume increases. In a closed plu...
Make up water in eachexpansion tank.───各膨胀水柜补水。 英语使用场景 Note: The potable waterexpansion tankshall be installed in the cold water service pipe line on the supply side of the water heater. We suggest the use of a model DETexpansion tank, the Watts Governor 80 ball cock with...
Install the expansion tank on the cold water supply line to the water heater at a point between the water heater and backflow preventer or other one-way device (see Amtrol's instructions Figure 2.) Mount [hot water thermal expansion] tank vertically only Once the expansion tank is installed,...
Methods and apparatus for (a) increasing expansion tank acceptance (defined herein as working fluid storage capacity); and (b) adjusting the rate of pressure variations within a prespecified range in precharged fluid storage systems (for example, holding pressure down below a prespecified threshold ...
steelplateconvex steelpreheating steelruler steeltank steelworkers bankers steelyard machine steeldistribution steep acropolis steep pitch of thread steep spectrum source steep tall and straig steep water steepparch steepa steepness of pulse ed steer axle kingpin steer for steerable nozzle with steered bea...
Using the tank pressure and the ambient temperature as stagnation properties and knowing the cold outlet pressure, the static temperature at a lower pressure can be evaluated. Xue et al. [50] compared an isentropic expansion, the Joule-Thompson expansion and a free expansion with real gas model...
they still complain of "clicking" noises, mainly during the heating season. Does the location of the expansion tank (3 horizontal feet from the 50-gallon hot-water heater) and check valve (1 1/2 feet from the water heater on the feed side of the water line) have anything to do with ...
Solar Aqualeader tanks are quality tested at several stages on the production line to insure the structural integrity of every tank. Solar Aqualeader tanks represent the best value for the investment and are the best quality pressure vessels available today. Single Diaphragm Pressure Vessel ...