Streck ESR-Auto Plus 自动红细胞凝集率仪说明书 ESR-Auto Plus® An automated sedimentation rate analyzer.The ESR-Auto Plus automated analyzer is designed to accurately and precisely measure the sedimentation rate of erythrocytes in ESR-Vacuum Tubes.y Safety-Coated Tubes Mylar blood specimens in the ...
The method for measuring the erythrocyte sedimentation rate (ESR) recommended by the International Council for Standardization in Haematology (ICSH) and other national authorities is based on the method described by Westergren in 1921 for studying patients with pulmonary tuberculosis. Essentially it is ...
[KeyWOrds]Erythrocytesedimentationrate(ESP,);AutomaticESRanalyzer;Westergrenmethod 红细胞沉降率(ESR)简称血沉是临床常用的传统 检验项目,在辅助疾病诊断和观察疾病疗效等方面具 有一定的参考价值。国际血液学标准化委员(ICSH)推 荐魏氏法为血沉测定的标准方法,但魏氏法存在不足 如检测时限长、存在生物危害隐患、人为...
ESR testing has important guiding significance for many clinical diseases, but the traditional standard Westergren method has complicated operation, low work efficiency and large cross-contamination. Automatic ESR analyzer uses advanced infrared light color difference i...
addition, it saves the costs that would otherwise be incurred for the purchase, maintenance, consumables, and storage space of a separate ESR analyzer. Compared with the traditional Westergren method, this method performs better in quality traceability, repeatability, speed, safety, and lev...
楼上讲的差不多了,这里补充一点点~Erythrocyte Sedimentation Rate (ESR)(红细胞沉降率)The distance that red blood cells settle in a tube of blood in one hour.(一小时内红细胞沉降距离)一般用魏氏法测量: 【Westergren method(魏氏法,国际血液学标准化委员会推荐魏氏法为标准法)】男性...
Our results suggest that viscosity method is better than ESR in measuring erythrocyte aggregation . 黏度法比红细胞沉降率法更好地反映了红细胞的聚集性。 RDW was determined with automatic blood analyzer and ESR was determined by Westergren method . 采用全自动血液分析仪测定RDW,采用魏氏法测定ESR。 An ...
50Hz/60Hz(±1Hz)Power input 600VA External output LANx1,USB x4(Specifications:DC5V;500mA;USB2.0x3;USB3.0x1)Physical Specifications Normal Operating Environment Key Specifications RBC,PLT Focusing Flow-DC Impedance Method HGB Colorimetric method ESR Photometric method Number of measuring parameters(...
Main Features: Better compatibility compared with Westergren method. A safe,reliable and airtight operation during the whole process from blood collection to test, free of biological contamination. Designed with spirit level or patent technology, which ensures the detector horizontal and aclinic. ...
The Diesse CUBE 30 Touch carries out automated, high-volume erythrocyte sedimentation rate testing with excellent correlation to the Modified Westergren method and does not require a dedicated tube, as it is compatible with standard 13 x 75 mm K2EDTA and K3EDTA tubes (1.5-4.0 mL). By running...