Some of our ESD benches have the wrist strap going directly to ground and others to a work bench ESD mat which (on the opposite corner) then goes through a common point ground cord with a resistor to ground. Which is right? Neither are necessarily correct because of the dependency on the...
adds redundancy and eliminates residual static charges. •Typical resistance is 10e6 ohms (1 megohm) to 10e7 ohms (10 megohms) at 40 to 60% relative humidity.•Two banana jacks for wrist strap plug-in •Two lugs and ground wires•BenchPro workbenches and tops will not lose their E...
adds redundancy and eliminates residual static charges. •Typical resistance is 10e6 ohms (1 megohm) to 10e7 ohms (10 megohms) at 40 to 60% relative humidity.•Two banana jacks for wrist strap plug-in •Two lugs and ground wires•BenchPro workbenches and tops will not lose their E...
The pass/fail combo unit requires no computer, making it more cost effective for companies that do not need to record data. Specifications: Power supply: 9-volt battery or 12-volt DC adapter (US) Test voltage: 19 volts DC ± 1 volt (open circuit) Resistance range: Wrist strap: Low: ...
Meaning, from a practical real world perspective, if a board is so susceptible to static damage, then you can just assume your going to get back 100% from customers because even though you might gingerly handle them in manufacturing insuring their always in perfect anti-static bags, and have...
Switching PSUs usually have ~100pF caps to earth at the primary side, so my computer was slightly energizing it, normally ok but now was floating! I noticed a slight electric tickling in my fingers when soldering, couldn't be more than a few microamps or I would have had a serious sho...
aMany of the components mounted on a PCB (including the TMP006) are susceptible to damage by electrostatic discharge (ESD). Customers are advised to observe proper ESD handling precautions when handling the TMP as configured on a PCB, including the use of a grounded wrist strap at an approved...