The controller has a version number of '1' (0x00000001). The controller has an insertion length of '16' (0x00000010). This utility will attempt to reset the controller. A error occurred while attempting to reset the controller. ---[An error has occurred and this util...
芯片型号TMS320C6747,新的一批板子,之前都正常使用,今天上电ccs报错2131,首先对着csdn一顿搜索测试,引脚用万用表测试都未短路,供电和晶振工作都正常,经过一番查找This error means the JTAG debugger is unable to access the core or device on the board. JTAG 调试器无法访问板上的内核或设备,下面的网址提供了...
Error connecting to the target: (Error -2131 @ 0x0) Unable to access device register. Reset the device, and retry the operation. If error persists, confirm configuration, power-cycle the board, and/or try more reliable JTAG settings (e.g. lower TCLK). (Emulation package 5.0.569.0) ...
error connecting to the target: (error - 2131 @ 0x0) Unable to access device register. Reset the device, and retry the operation. If error persists, confirm configuration, power-cycle the board, and/or try more reliable JTAG settings (e.g. lower tclk). ...
If you have a related question, please click the "Ask a related question" button in the top right corner. The newly created question will be automatically linked to this question. Original question: CCS/TMS320F28379D: C28xx_CPU1: E...
connectingto thetarget: (Error-1143 @0x0)Devicecore was hung. The debugger has forced thedeviceto a cxad2018-06-21 04:25:20 在Debug时,出现Errorconnectingto thetarget: 在Debug时,出现Errorconnectingto thetarget:(Error-1135 @0x0)The emulator reported anerror. Confirm ...
在Debug时,出现Errorconnectingto thetarget:(Error-1135 @0x0)The emulator reported anerror. Confirm cnibooji2018-11-13 14:49:26 在用CCS5.5Debug时遇到Errorconnectingto thetarget问题 在debug时,出现C28xx:Errorconnectingto thetarget:(Error-1135 @0x0)The emulator reported anerror ...
CTC cannot navigate to the target tab. {0} CTC cannot go to the specified target tab. EID-3081 The port type cannot be changed. Refer to the error message text. EID-3082 The {0} extension byte cannot be changed. You cannot modify the specified extension byte. EID...
CTC cannot navigate to the target tab.{0} CTC cannot go to the specified target tab. EID-3081 The port type cannot be changed. Refer to the error message text. EID-3082 The {0} extension byte cannot be changed. You cannot modify the specified extension byte. EID-...
2515Connecting to the Remoteboot server...NERR_CallingRplSrvr 2516Connecting to the Remoteboot server...NERR_StartingRplBoot 2517Remote boot service was stopped; check the error log for the cause of the problem.NERR_RplBootServiceTerm 2518Remote boot startup failed; check the error log for the...