John Goodge, University of Minnesota-Duluth Interaction of an electron beam with a sample target produces a variety of emissions, including x-rays. An energy-dispersive (EDS) detector is used to separate the ...Goodge, JohnD. Shindo and T. Oikawa, "Energy Dispersive X-ray Spectroscopy," in...
A typical analytical electron microscopic method (i.e., energy dispersive X-ray spectroscopy, or EDS, sometimes called EDX or EDXS) is described in this chapter. Although some improvement in the resolution of EDS has been attempted, there has been no significant modification introduced in the pr...
1 Introduction to Energy Dispersive X-ray Spectrometry (EDS) 1. Introduction 1.1 Principles of the technique EDS makes use of t..
X-Ray Fluorescence Spectroscopy, Applications* ChristinaStreli, ...P.Kregsamer, inEncyclopedia of Spectroscopy and Spectrometry (Second Edition), 1999 Instrumentation and Methodology Wavelength-Dispersive Spectrometers Two types of WD instruments are in use, the sequential spectrometer and the simultaneous ...
Introduction to Energy Dispersive Xray (介绍了能量色散x光).pdf,Introduction to Energy Dispersive X-ray Spectrometry (EDS) 1. Introduction 1.1 Principles of the technique EDS makes use of the X-ray spectrum emitted by a solid sample bombarded with a foc
Infrared spectroscopy(IR),scanning electron microscope(SEM) and energy-dispersive X-ray analysis(EDX) were used to analyze nutrients in four pine pollen po... YM Wang,HJ Wang - 《Spectroscopy & Spectral Analysis》 被引量: 21发表: 2005年 Evaluation of micro-energy dispersive X-ray fluorescence...
ENERGY-DISPERSIVE X-RAY ANALYSIS OF BIOLOGICAL MICRODROPLETS**This work was supported by the George Frankel Research Scholar Award to the author from the National Cystic Fibrosis Foundation and by a research grant from the Southern California Kidne...
The solvothermal synthesis of the three-dimensional germanate (1, {2-DAPH2)2Ge9(OH)4O18} 2 {H2O} has been studied with the in-situ energy dispersive X-ray powder diffraction technique {(EDXRD).} The temperature dependence of the extent of reaction (alpha) has been...
The environmental scanning electron microscope (ESEM) is not typically used for quantitative analysis by energy dispersive x-ray spectrometry (EDS) because the electron beam is scattered by the chamber gas forming a broad tail or skirt rather than a focused spot. Scattered electrons can contribute ...
- 《Spectrochimica Acta Part B Atomic Spectroscopy》 被引量: 11发表: 2009年 Thermoelectrically cooled semiconductor detectors for portable energy-dispersive x-ray fluorescence equipment Thermoelectrically cooled semiconductor detectors, such as Si- PIN, Si-strip and HgI2, coupled to miniaturized low-...