seismic designelevated cone-shaped water tankshydrodynamic effectsIn this paper a model is discussed that allows a simple calculation of seismic effects on an elevated water cone-shaped tank. In particular, following on from the complete model of De Stefano and by means of the classic mechanical ...
Design Principles of Photovoltaic Irrigation Systems JuanReca-Cardeña,RafaelLópez-Luque, inAdvances in Renewable Energies and Power Technologies, 2018 2.2.1Pumping to an Elevated Tank Storing the pumped water into anelevated storagetank is a sound procedure for matching therenewable energy productionto...
Photoelectrochemical (PEC) water splitting is a promising approach for sustainable hydrogen production. Previous studies have focused on devices operated at atmospheric pressure, although most applications require hydrogen delivered at elevated pressure.
The paper puts emphasis on design of large volume reverse cone-shaped water tower and water tank and method of calculation of each component of water tower,and the paper analyzes many problems concerning the design of large volume water tower to which attention shall be paid. 重点阐述了大容积...
Climate change impact has disturbed the rainfall pattern worsening the problems of water availability in the aquatic ecosystem of India and other parts of the world. Arsenic pollution, mainly through excessive use of groundwater and other anthropogenic a
This research begins with employing a two-mass coupled model as a simplified approach to provide preliminary hand-made design checks for two real case studies of elevated reinforced concrete tanks; Step 2: Calculation of Key Quantities. Calculate the main quantities involved in the two-mass coupled...
After the weighing, the samples were put back into the water tank for continuous immersion. In order to reduce the experimental error, the whole weighing process was controlled within 15 min. Five samples were weighed and the average value was obtained. The water absorption of two kinds of ...
In order to validate the developed program for the proposed RC pile caps, conventional design was arrived with manual calculation and the results were compared.doi:10.21090/ijaerd.62754Regupathi RSugumar R
The examination of VOCs emitted from five locations of the BVSW landfill allowed the calculation of the health risk index of exposed workers. The highest risk index associated with the point source and the leachate tank is indicative of the proximity of the source of elevated temperature and the...
The calculation cell dimension was 0.1 m for a single room and 0.2 m for the layout of rooms. 3. Definition of Dedign Fire The fire power density was assumed for hospital rooms with patients staying at 250 kW/m2. As a consequence, for the area of the analyzed room No. 11, which wa...