搜本公司搜全站 优势供应FRAKO LKT15-440-DP 电容 价格:面议 最小采购量:不限 主营产品:传感器,编码器,泵阀及各类仪器仪表 供应商:上海祥树实业发展有限公司 所在地:中国 联系人:朱军 联系电话 点此询价 QQ咨询 买家还在看 瑞士丹青 Sylvac S_Screw ... ...
When a qualifying WoL frame is received, the DP83825I WoL logic circuit is able to generate a user-defined event (either pulses or level change) through any of the GPIO pins or a status interrupt flag to inform a connected controller that a wake event has occurred. Additionally, the DP...
A device will be defined as a failure if after exposure to ESD pulses the device no longer meets the device specification. Complete DC parametric and functional testing is performed per the applicable device specification at room temperature followed by hot temperature, unless specified otherwise in ...
Kral AG(Volumeter) OME13.3015147 0.1-10l/min 0-40bar -20-125℃ G1/2 K1 pulses/lIMAV SBV 11-12N-C-0-024DGHparker FGK2101PAM+S HYDRAULIC MSQ-315-SHPKUEBLER 8.5020.D551.2048B&R 8V1090.00-2tecsis GmbH E1931X400030Settima GR40 SMT16B 100L AC24 G HDECKARDT FRS923-2SV-FGuntermann & ...
Kral AG(Volumeter) OME32.3015747 1-100l/min 0-40bar -20-125℃ G1 K1 pulses/ 78NASS MAGMET 0542 34.1-00/5147 Nr.108-030-0181hydac EDS 345-1-400-000Kral OMX 13.0225347 OMX13+UOD253+BEG47Bwalther electric 63A 5P 400V 6h IP67 269SCHUNK 0340310 KGG 80Karl Klein ENG 2-5D/S S/N:...
2048 pulses / revolution, hollow shaft, shaft 20mmJANE D421.51U1JANE 3207332b40 JANE KS60-03/250/5/5VA current converter250A/ 5A/ 5VAJANE KS60-03/250/5/5VA current transformer 250A/ 5A/ 5VAJANE 01.NR 630.10VG.10.BP-NOT CLEANABLEJANE Gland for HWR 240KJANE 0543 00.1-00 BV5763 ...
Features Overview 13-1132 BCDCardJumperTable 13-3133 Interconnect Board 13-3134 50-LineCableCompatibi l ity 13-4 ”135 Selecting the source of BCD Data: “OUTCNF” 13-4136 HoldControl 13-4137 DataReadyTimingPulses 13-4138 Bringingout theBCDOverflowl ine 13-4139 3DigitatatimeMultiplex 13-...
After the pulse transmission, the DP83825I measures the return time and amplitude of all these reflected pulses. This technique enables measuring the distance and magnitude (impedance) of non-terminated cables (open or short), discontinuities (bad connectors) and improperly terminated cables with ±...
When three consecutive inverted link pulses are received, bad polarity is reported. A polarity reversal can be caused by a wiring error at either end of the cable, usually at the Main Distribution Frame (MDF) or patch panel in the wiring closet. The bad polarity condition is latched in the...
A ballast for powering a fluorescent lamp with filaments requiring preheating. Control circuitry within the ballast delays an igniter from being turned on until the filaments have been sufficiently preheated. The control circuitry is isolated and thereby protected from the high voltage pulses of the ...