- 《Veterinary Radiology》 被引量: 104发表: 1987年 Stress fracture as a complication of autogenous bone graft harvest from the distal tibia. LB; Mann, RA; Coughlin, MJ; McPeake, WT, 3rd; Mizel, MS: Stress fracture as a complication of autogenous bone graft harvest from the distal tibia....
Marmor L: An unusual fracture of the tibial epiphysis. Clin Orthop 73:132–135, 1970 PubMed CAS Google Scholar McNiesh LM: Unique musculoskeletal trauma. Radiology Clin NA 25:1107–1132, 1987 CAS Google Scholar O’Connor D, Mulligan M: Extra-articular triplane fracture of distal tibia: ...
Pediatric RadiologyO’Connor DK, Mulligan ME. Paediatr Radiol. Extra-articular triplane fracture of the distal tibia; a case report. 1998;28(5):332–3.O’Connor DK, Mulligan ME. Extra-articular triplane fracture of the distal tibia: a case report. Pediatr Radiol. 1998;28:332–3....
Screw home mechanism: As the knee is brought into full extension, the tibia externally rotates on the femur with the medial tibial plateau riding along the curvature of the medial condyle. This mechanism “locks” the knee in terminal extension. • The strongest bone is found posteriorly on ...
Insufficiency fracture of the talus: diagnosis with MR imaging. one in the distal tibia and one in the calcaneus.The location and orientation of talar insufficiency fractures is more variable than previously recognized. ... Umans,Pavlov - 《Radiology》 被引量: 50发表: 1995年 ...
QUANTITATIVE ULTRASONOGRAPHY FOR ASSESSMENT OF BONE MINERAL DENSITY IN THE CANINE RADIUS AND TIBIA Quantitative ultrasound allows noninvasive assessment of cortical bone density. Potential applications include monitoring of fracture healing, rehabilitati... SK Lauer,ES Davies,G Hosgood,... - 《Veterinary...
Thus, in fracture reduction, the lateral tibial plateau articular edge should be slightly more lateral and not medial to the lateral articular edge of the distal femur. Similarly, the medial articular edge of the tibia should be slightly more medial and not lateral to the medial articular edge ...
Distal TibiaPlating System Monoaxial locking plate system for treating distal tibia fractures. Plating that fits. We understand the importance of a well-fitting implant. An implant that fits may reduce OR time, may decrease fracture malalignment, and potentially reduce patient discomfort, especially in...
The tibia also has a mechanical axis (the mechanical axis of the tibia) which runs from the knee joint line to the center of the ankle joint. Both femurs naturally converge towards the knee. This degree of convergence is measured and recorded as the angle of convergence. Variation in the ...
These studies reconstructed the four bones of the knee (femur, patella, tibia and fibula) with an average chamfer of 1.87 mm. As in our method, they used DRR images generated from CT data as training data, translated into DRR-like images when adapting the X-ray images. They used a ...