Ensure all inlet and outlet manual valves on the main loops (raw water supply, heater, pre-treatment) are 23、 opened. 确认所有主输水管道(原水进水、加热器、预处理)进水及出水手动阀门均已开启;4. Ensure all bypass and drain valves are closed. 确认所有旁通及排水阀门均已关闭;5. Switch all ...
Water Yield (25°c) 10L/H Instantaneous Water Yield 1.5-2.0L/Min (Pressure Barrel Is Needed) Resistivity 13-17.5mΩ 2.Cm@25c Heavy Metal Lon <0.1pbb Pm (>0.2um) <1/Ml Lon Rejection Rate 96%-99%(When New RO Film I...
5.TDS (total solids solubility): RO water:5~10 ppm; 6.Resistivity: 7.0~10.0 MΩ·cm; 7.PM (particulate matter) (>0.22μm): <1/ml; 8.Conductivity: 0.143~0.100 μs/cm; 9.Microbe/Germ: <1 CFU/ml Water Quality Monitor TDS (Total Dissolved ...
TDS (total solids solubility): RO water:5~10 ppm; Resistivity: 10~18.25 MΩ·cm; PM (particulate matter) (>0.22μm): <1/ml; Conductivity: 0.055~0.1 μs/cm; Microbe/Germ: <1 CFU/ml Water Quality Monitor TDS (Total Dissolved Solids) meter Consumption 46W 113W...
TDS (total solids solubility): RO water:5~10 ppm; Resistivity: 7.0~10.0 MΩ·cm; PM (particulate matter) (>0.22μm): <1/ml; Conductivity: 0.143~0.100 μs/cm; Microbe/Germ: <1 CFU/ml Water Quality Monitor TDS (Total Dissolved Solids) meter Consumption 48W ...
Ultrapure Water Quality Resistivity(25°C) 18.2MΩ.cm Heavy Metal Ion <0.1ppb TOC <10ppb <10ppb <3ppb <3ppb Bacteria <0.1cfu/ml Endotoxin N/A <0.001Eu/ml N/A <0.001Eu/ml Particle(>0.2μm) <1/ml RNases N/A <0.01ng/ml N/A...
FOXBOROPressure Transmitter 13A-1 0-125 Inches Water w/ Valve FOXBOROPressure Transmitter 1GP10-D22D1F-L1F FOXBOROPRESSURE TRANSMITTER 823DP TRANSMITTRER FOXBOROPRESSURE TRANSMITTER GAUGE 1DP10-I20B2`1F-M1 FOXBOROPRESSURE TRANSMITTER GAUGE 1GP10-1201F ...
9-50-DKRS Reliance 50-Gallon Electric Water Heater RELIANCE ELECTRIC 079165-22-SA USPP 07916522SA RELIANCE ELECTRIC F52B0624A NSPP F52B0624A RELIANCE ELECTRIC M6257530130R USPP M6257530130R RELIANCE ELECTRIC MFC39009-PF USPP MFC39009PF RELIANCE ELECTRIC 0-54200 USPP 054200 RELIANCE ELECTRIC 0-59006...
TDS (total solids solubility): RO water:5~10 ppm; Resistivity: 7.0~10.0 MΩ·cm; PM (particulate matter) (>0.22μm): <1><200ppm, 5=""> Conductivity: 0.143~0.100 μs/cm; Microbe/Germ: <1 cfu=""> Water Quality Monitor TDS (Total Dissolv...
H2O (ultra-pure)Resistivity: 18 MΩ · cm Electrodeposition is performed at room temperature. Heating the elements, notably the radioactive elements such as curium, at temperatures where dangerous reactions may occur, is thereby avoided. The optimized experimental conditions of the electrodeposition are...