In order to increase the accuracy of non-invasive glucose measurement, the device uses a combination of three non-invasive methods: ultrasonic, electromagnetic and thermal. The non-invasive glucose monitor comprises a Main Unit, which drives three different sensor channels (one per technology), ...
in order for a device to measure a distance with the help of a l u00e4ngen u00e4nderungen along the path fraught me u00dfbandes (3), with a me u00dfstreckenende verschiebefest is kept and the other me u00dfstreckenende with a l u00e4ngenme u00dfskala (15) and a ablesemark ...
摘要: PROBLEM TO BE SOLVED: To provide a capillary apparatus, capable of easily collecting a gingival groove liquid difficult to collect to measure a blood sugar value in a noninvasive manner, a tester, a measuring method and a monitoring method....
The implanted sensor works with a novel light-based technology to measure glucose levels and send information to a mobile app to alert users if glucose levels are too high or too low. The sensor is coated with a fluorescent chemical which, when exposed to blood sugar, produces a small amount...
It is recognized that a device to measure glucose continuously without requiring finger stick blood samples would be a major step forward. At minimum, it would provide the patient with timely information to make insulin injections or adjust his insulin pump. Further, it could be used to control...
MIT device may allow glucose testing minus the finger pricks. (cover story)The article focuses on the research study by researchers at Massachusetts Institute of Technology's (MIT) Spectroscopy Laboratory in August 2010 on a noninvasive technique for diabetes patients to measure blood glucose levels...
Continuous glucose monitoring device It is recognized that a device to measure glucose continuously without requiring finger stick blood samples would be a major step forward. At minimum, it would provide the patient with timely information to make insulin injections or adju... Haar, Hans-peter,H...
breath alcohol testing instrument manufacturer, the driver is made to breathe on an inlet of the blood alcohol testing device, to then enable the blood alcohol testing device to measure alcohol concentration from a breath sample and externally display a result of the measured alcohol concentration. ...
A device to measure the oxygen uptake rate of attached cells: importance in bioartificial organ design. L., “A device to measure the oxygen uptake rate of attached cells: importance in bioartificial organ design.,” Cell Transplant. 3, 515-527, 1994... ...
wherein the drug delivery unit is in communication with the implantable sensor unit and releases the therapeutic agent in response to the sensor's sensing of the environmental component. For example, the sensor can measure a patient's glucose level and the drug delivery unit can release insulin....