Chest compressionsNeonatal Resuscitation Program (NRP) guidelines recommend chest compression depths of 1/3 the anterior–posterior (AP) chest depth. Appropriateness of this recommendation has not been rigorously assessed. To compare the efficacy and safety of neonatal chest compression depths of 1/4, ...
Computerised-tomography images of the thorax of 55 patients with a diagnosis of obesity or morbid obesity (mean BMI 45.95 kg/m2) were evaluated to determine the depth of SAT at the level at which chest compressions would be applied by a trained rescuer, and correlated with BMI. Mean ...
The graph shows data for 40 children, half of whom were male (M) and half of whom were female (F), in each of three age groups: at least 9 but less than 10 years old, at least 11 but less than 12 years old, and at least 13 but less than
Since chest compressions were first introduced more than 50 years ago, there has been increasing emphasis on the importance of compression depth. Increasing depth is associated with a higher blood flow, and a compression depth of at least 5 cm is the current recommendation [1]. Whereas this is...
Increased blood pressure and depth of chest compressions does not improve cardiac output or organ perfusion in a swine model of pediatric cardiac arrestMao, CClay, MBone, CVintenJohansen, JMaher, K
Can thoracic impedance monitor the depth of chest compressions during out-of-hospital cardiopulmonary resuscitation?[J]. Resuscitation, 2014, 85(5): 637-643.Can thoracic impedance monitor the depth of chest compressions during out-of-hospital cardiopulmonary resuscitation?[J] . Erik Alonso,Digna ...
A method of processing a raw acceleration signal, measured by an accelerometer-based compression monitor, to produce an accurate and precise estimated actual depth of chest compressions. The raw acceleration signal is filtered during integration and then a moving average of past starting points ...
A method of processing a raw acceleration signal, measured by an accelerometer-based compression monitor, to produce an accurate and precise estimated actual depth of chest compressions. The raw acceleration signal is filtered during integration and then a moving average of past starting points ...
一种胸外按压深度的监测方法,系统和除颤仪 A method for monitoring the depth of chest compressions, and defibrillation system本发明提供一种胸外按压深度的监测方法和系统. The present invention provides a method and system for monitoring chest compression depth. 该监测方法包括:获取胸外按压校准过程的参考...
Chest heightChest compression forceChest compression depthIntroduction: The LUCAS 2 device stores technical data that documents the chest compression process. We analyzed chest wall dimensions and mechanics stored during chest compressions on humans using data gathered with the LUCAS 2 device.Beesems, ...