Dell EMC Networking S4048-ON and S4048T-ON Switch Configuration Guide for Dell EMC SC Series and Dell PS Series SANs Abstract This document illustrates how to configure Dell EMC™ Networking S4048-ON and S4048
guide 5 Related documents 5 Chapter 2: The S4048–ON switch 6 Introduction6 Features 7 Physical dimensions7 Switch status8 LED display8 LED behavior9 Prerequisites 10 S4048–ON configurations11 Chapter 3: Site preparations12 Site selection12 Cabinet placement12 Rack mounting 13 Switch ground13 ...
S4048-ON supports feature-rich Dell EMC Networking OS9 and Dell EMC SmartFabric OS10, VLT, network virtualization features such as VRF-lite, VXLAN Gateway and support for Dell Embedded Open Automation Framework. • The S4048-ON is the only switch in the industry that provides customers an ...
If you insert a non-Dell qualified 40G transceiver into a S4048T-ON 40GbE port, the switch places the interface in an error-disabled (operationally down) state and generates a syslog message, such as: %S4048LC0640:8 %IFAGT-2- TRANSCEIVER_UNSUPPORTED_ERROR: Transceiver in slot 1 port 49...
Customer-supplied vSphere Distributed Switch (vDS) is a new feature supported by VxRail Manager 7.0.010 that allows customers to create their own vDS and provide it as an input to be utilized by the clusters they build using VxRail Manager. VMware Cloud Foundation on Dell E...
The dell_enterprise_switch_deduplicate_clear 触发器将关联 S 系列,M 系列,Z 系列和 C 系列交换机问题事件. The dell_nseries_deduplicate_clear 触发器将关联 N 系列交换机问题事件. 带内 Dell EMC 服务器的传统和增强的事件消息格式陷阱不提供事件自动关联支持. 由于 Netcool/OMNIbus 定期清理正常事件,因此不...
Describe the DHCP and NTP service and explain the configuration steps Describe basic routing concepts and explain how to interpret a routing table Topic 4 Describe the switch models that are part of the Dell EMC Campus, Datacenter Explain the purpose and basic operations of the OSI model Topic ...
The connections are made to a pair of Pod switches, to provide redundancy in the case of port, cable, or switch failure. The switch ports are configured as a LAG. Connections to the BMC network use a single connection from the iDRAC port to a S3048-ON management switch in each rack. ...
• dell_equallogic_clear • dell_equallogic_deduplicate_clear Dell EMC Enterprise(S-Series,M-Series,Z- Series,および C-Series)イベントが相関されない 次のトリガが Netcool/OMNIbus ObjectServer で有効になっていることを確認します. • dell_enterprise_switch_clear • dell_enterprise_...
It is applied at boot time prior to starting the switch firmware and reading the startup configuration. Stack information shown in the startup and running configurations is simply repeating information from the meta-data for the user’s knowledge. Therefore, if the startup configuration is deleted...