开机按F2进入System Setup管理界面 2.选择Device Settings 3.选择Integrated RAID controller 1:DELL PERC<RAID卡型号> Configuration Utility(不同的机器配置raid卡不同,但方法相同)4.选择Main Menu 5.选择Configuration Management 6.选择Create Virtual Disk 7.通过Select RAID level先选择需要创建的RAID级别后,点...
If you are using an old server that uses PERC/CERC BIOS Configuration Utility, please refer to the article we wrote earlier abouthow to create RAID on DELL Servers using PERC/CERC BIOS Configuration Utility(with screenshots). 1. Launch PERC 6/i Integrated BIOS Configuration Utility Fir...
S130FD332内部控制器PERC FD33xS(单 PERC)、FD33xD(双 PERC) 安全性 FC640:加密签名的固件安全引导服务器配置锁定安全即时擦除功能 管理 FC640、FC830、FC430、FD332: 嵌入式/服务器级Chassis Management Controller (CMC)iDRAC9 iDRAC DirectiDRAC RESTful API(采用 Redfish)控制台OpenManage EnterpriseOpenManage ...
S140外部HBA(非 RAID)12 Gbps SAS HBA外部PERC (RAID)H840启动优化型存储子系统HWRAID:2 个 M.2 SSD(120 GB、240 GB) 安全性 加密签名的固件安全启动 安全擦除晶片信任根系统锁定(需要 OpenManage Enterprise)TPM 1.2/2.0、TCM 2.0(可选) 管理 嵌入式/服务器级iDRAC9 iDRAC DirectiDRAC RESTful API(采用...
PERC PowerEdge 可扩充 RAID 控制器 (PowerEdge Expandable RAID controller) 的缩写.这是 Dell 专用的 RAID 控制器. PGA 插针栅极阵列 (pin grid array) 的缩写,一种用以卸下微处理器芯片的微处理器插槽. POST 开机自测 (power-on self-test) 的缩写.打开系统后,POST 程序将在载入操作系统之前检测各种系统...
1. Launch PERC H700 Integrated BIOS Configuration Utility Insert all new disks into the empty slots. If there are already disks on slot 0 and slot 1, start inserting the new disks from slot 2. In this example, the new 4 disks are inserted from slot-2 to slot-5. ...
• Dell Update Packages User's Guide(Dell Update Package 用户指南)提供了有关获取和作为系统更新策略的一部分使用 Dell Update Package 的信息. • Dell Shared PowerEdge RAID Controller (PERC) 8 User's Guide(Dell Shared PowerEdge RAID Controller (PERC) 8 用户指南)提供 关于部署共享 PERC 8 卡和...
For more information about software RAID, see the Dell PowerEdge RAID Controller (PERC) documentation at dell.com/storagecontrollermanuals. Eight hard-drive systems Ten hard-drive systems Up to eight 2.5-inch, hot-swappable SAS, SATA, SATA SSD, or Nearline SAS hard drives Up to ten 2.5-inch...
PERC with rear 2 CS SATA drives) Supports SATA drives in the rear for boot or as a hot tier (2.5-inch SATA SSDs would have to be hosted in a 3.5-inch carrier) Config 3 24x3.5-inch and 2x3.5-inch (12+12 1st PERC and 2x3.5-inch 2nd PERC) Front 24 drives on Mini PERC ...
• —s—This option returns the status of the update process. • -a—The -a option specifies TFTP server IP address that is used for firmware image. This option must be used with the -g option. • -clearcfg—The -clearcfg option removes the previous iDRAC configuration after ...