aBefore commencing any hazardous work operations, CONTRACTOR shall inspect the Jobsite and equipment involved to ensure the WORK will be performed under safe conditions acceptable to COMPANY CONTRACTOR shall verify that all procedures are adhered to prior to initiating any hazardous work. 在开始任何危害...
Open-chest or internal defibrillation should be performed when the sternum is already open during surgery or is reopened after surgery. Paddles made specifically for this purpose are applied directly to the heart. Internal paddles have diameters of 6 cm for adults, 4 cm for children, and 2 cm...
Conventional transvenous defibrillation is performed with an ICD using a dual current pathway. The defibrillation energy is delivered from the RV electrode to the superior vena cava (SVC) electrode and the metallic case (CAN) of the ICD. Biventricular defibrillation uses an additional electrode ...
To test the hypothesis that selective brain cooling could be performed in an infant model of cardiac arrest and resuscitation without changing core tempera... B Gelman,CL Schleien,A Lohe,... - 《Resuscitation》 被引量: 250发表: 1996年 ...
If paramedics reached the patients before, or simultaneously with, the first responding EMTs, manual rhythm recognition and defibrillation were carried out after instituting CPR, which was performed until the device was readied. When EMT responders arrived first, AEDs were applied to individuals with...
This study demonstrates that the use of drones for automated AED delivery to a bystander at the site of an OHCA in a non-urban area with physical barriers is feasible and leads to a shorter TTD compared to a bystander using PAD and HEMS physician performed defibrillation. The TTD was indepen...
Thankfully, the relatively recent advent of automated external defibrillators means that defibrillation can now be performed safely by healthcare assistants (HCAs) and assistant practitioners (APs), ideally before the arrival of the resuscitation team or ambulance. This article explains the ...
In a next step 73, it is determined whether defibrillator/pacer 8 should remain in the pacing mode. If defibrillator/pacer 8 is to remain in the pacing mode, the process returns to step 71. Otherwise, a step 74 is performed in which external combined defibrillator/pacer 8 returns to a st...
At the conclusion of the waiting period (44), defibrillator 12 may prompt the operator to discontinue CPR (48) or, when CPR is performed by a chest compressor, defibrillator 12 may direct the device to discontinue CPR. Defibrillator 12 may deliver defibrillation therapy (50). [0039] The ...
Is the determination of the defibrillation threshold in patients with an implantable cardioverter–defibrillator still required?Is the determination of the defibrillation threshold in patients with an implantable cardioverter–defibrillator still required?Implantable cardioverterdefibrillator...