Parameter list VLT Parameter Description Default Desired Setting 8-01 Control Side Digital Ctrl. Word 8-02 Control Source FC Port FC Port 8-03 Control Word Timeout 60 s 1-18000 s 8-30 Protocol FC Metasys N2 8-31 Address 1 1-255 8-32 Baud Rate 9600 Fixed to 9600 8-33 Parity Even,...
VLT®isaregisteredtrademarkforDanfossA/S.1.2AdditionalResourcesOtherresourcesareavailabletounderstandadvanceddrivefunctions,programming,andmaintenance.lTheVLT®MidiDriveFC280ProgrammingGuideprovidesinformationonhowtoprogramandincludescompleteparameterdescriptions.lTheVLT®MidiDriveFC280DesignGuideprovidesdetailedinformation...
21 Parameter Set-up VLT® Motion Control Tools MCT 10 Set-up Software 5 Parameter Set-up This chapter explains how to control a frequency converter using the MCT 10 Set-up Software. After starting the MCT 10 Set-up Software, the main window looks like the example shown in Illustration ...
2.1.10. Software Version and Approvals: VLT AQUA Drive VLT AQUA Drive Operating Instructions Software version: 1.00 This Operating Instructions can be used for all VLT AQUA Drive frequency converters with software version 1.00. The software version number can be seen from parameter 15-43. 2.1.11...
the LCP (including the parameter setting) and all installed optionswithout connection to mains. 從哪裡購買 + 新增至比較表 +Add to My Product List 130B1272 VLT® Sensor Input Card MCB 114, coated MCB 114 - PT100 / PT1000 optionFor FC100-FC200 a...
28 MG.90.U2.02 - VLT? is a registered Danfoss trademark PROFINET Operating Instruction Bits 13/14, Set-up selection Bits 13 and 14 are used to choose between the four parameter set-ups according to the following table: The function is only possible if Multi Set-up has been chosen in ...
(AMA) without T27 123 8.1.4 Wiring Configuration: Speed 124 8.1.5 Wiring Configuration: Feedback 126 Danfoss A/S © 2021.10 AQ262139143212en-000301/130R0879 | 5 VLT® AutomationDrive FC 302 Operating Guide Contents 8.1.6 Wiring Configuration: Run/Stop 127 8.1.7 Wiring Configuration: Start...
the LCP (including the parameter setting) and all installed optionswithout connection to mains. 從哪裡購買 + 新增至比較表 +Add to My Product List 130B1272 VLT® Sensor Input Card MCB 114, coated MCB 114 - PT100 / PT1000 optionFor FC100-FC200 ...
11 Product Overview VLT® AutomationDrive FC 361 3.7 LCP Menus Q6 Loggings Quick Menu Mode Use Q6 Loggings for fault nding. To get information about the display line readout, select Loggings. The information is The Quick Menu mode provides a list of menus used to shown as graphs. Only...
Danfoss丹佛斯VLT® HVAC Drive FC 102, 110-400 kW 操作指南.pdf,Danfoss丹佛斯VLT®HVACDriveFC102,110-400kW操作指南用户手册产品说明书使用说明文档安装使用手册MAKING MODERN LIVING POSSIBLE Operating Instructions VLT® HVAC Drive FC 102 110-400 kW /drive