Generally speaking, the traditional lever amplification damping system is installed between adjacent columns in a building, which occupies a significant am... X Lan - 《Buildings》 被引量: 0发表: 2024年 Experimental Study on the Outrigger Damping System for High-Rise Building A novel energy-dissip...
Moon KS. Integrated damping system for tall buildings: tuned mass damper/double skin facade damping interaction system. Struct Design Tall Spec Build 2016;25(5):232-44.Moon KS (2010) Integrated damping systems for tall buildings: vertically distributed TMDs. In: 2010 ASCE structures congress, pp...
This paper presents integrated damping systems for tall buildings. An emphasis is placed on investigating the potential of double skin facades (DSF) as an integrated damping system for tall buildings. In the first scheme, the connectors between the inner and outer skins of the DSF system are ...
Damping Technologies for Tall Buildings provides practical advice on the selection, design, installation and testing of damping systems. Richly illustrated with images and schematics, this book presents expert commentary on different damping systems, giving readers a way to accurately compare between differ...
The response of tall buildings to naturally occurring forces is fundamentally affected by the way in which the energy input is dissipated by the structure. In choosing the mathematical convenience of a viscous damping coefficient, early workers and researchers solved their immediate problems, but bequea...
Seismic Behavior of Steel Buildings using Viscous Fluid Dampers by Non Linear Time History Analysis The aim of the present work is to reduce seismic response of structures using passive vibration control system namely Fluid viscous dampers in SAP2000. The... P Azarsa,M Hosseini,SA Ahmadi,... ...
The aerodynamic damping associated with shapes typical of tall buildings show several features of importance. The aerodynamic damping integrals for a square tower of height to width ratio of 6 ½ : 1 in a wind profile is shown in Fig. 17. It is seen that for almost all angles of attack...
Outrigger Tuned Viscous Mass Damping System for High-rise Buildings Subject to Earthquake Loadings And the design method for the TVMDs to be tuned to the bending of the building is introduced. Then the validity of the proposed damping system subject... T Asai,K Ikago,Y Araki 被引量: 0发表...
Thus, CRC can be used for the isolation of structural-borne noise in buildings, foundations, and industrial floors. Wang et al. [93], Benazzouk et al. [94], and Bignozzi et al. [95] also obtained similar conclusions in a study of CRC damping characteristics with different rubber ...
Active control of wind-induced vibrations in tall buildings using neural networks A neural network is proposed in the paper to provide active control to a building-tuned mass damper system using direct control by a modified backpropagati... AC Nerves,R Krishnan - International Conference on Industr...