[85]SiegbahnA, OldgrenJ, AnderssonU, et al. D-dimer and factor Ⅶa in atrial fibrillation-prognostic values for cardiovascular events and effects of anticoagulation therapy. A RE-LY substudy[J]. Thromb Haemost, 2016, 115(5):921-930. DOI: 10.1160/TH15-07-0529. [86]ChristerssonC, Walle...
[85]SiegbahnA, OldgrenJ, AnderssonU, et al. D-dimer and factor Ⅶa in atrial fibrillation-prognostic values for cardiovascular events and effects of anticoagulation therapy. A RE-LY substudy[J]. Thromb Haemost, 2016, 115(5):921-930. DOI: 10.1160/TH15-07-0529. [86]ChristerssonC, Walle...
[85]SiegbahnA, OldgrenJ, AnderssonU, et al. D-dimer and factor Ⅶa in atrial fibrillation-prognostic values for cardiovascular events and effects of anticoagulation therapy. A RE-LY substudy[J]. Thromb Haemost, 2016, 115(5):921-930. DOI: 10.1160/TH15-07-0529. [86]ChristerssonC, Walle...
D-dimer concentrations are elevated in a variety of clinical situations with hypercoagulability, such as venous thromboembolism (VTE), disseminated intravascular coagulation (DIC), ischemic cardiopathy, stroke, acute aortic dissection, malignomas, pregnancy, after surgery, traumas, and burns. D-dimer ...
(其中530份用于可比性验证,16份用于其他验证),根据美国临床和实验室标准协会(CLSI)指南、国家卫生行业标准和相关参考文献,分别对其在Sysmex CS 5100全自动凝血分析仪上的准确度、精密度、线性范围、携带污染率、抗干扰能力和参考区间进行验证,并与两种进口检测试剂(试剂A:Vidas D-dimer试剂;试剂B:Innovance D-二聚...
目的探讨AQT90 FLEX免疫分析仪床旁快速检测全血D-二聚体(D-dimer)的临床性能并评估其在老年患者中的应用价值。 方法参考我国卫生行业标准《D-二聚体定量检测》(WS/T 477-2015)中提供的设备性能评价方法,对AQT90 FLEX免疫分析仪检测全血D-二聚体(D-dimer)进行性能评价。选择2015年北京大学第一医院老年科60岁及...
The product is not cleared by FDA for monitoring of relative change in concentration of D-dimer in the US. 2. May vary dependent on type of analyzer utilized and mode of operation. Assay performance can vary from country to country as well as with the system application of the respective ...
一.Background introductionD-Dimer is a degradation product of cross-linked fibrin and an important marker of activation of the coagulation and fibrinoly...
29 D-dimer levels are therefore less likely to be useful in patients with suspected VTE and 1 or more of these diagnoses because, for example, increased values occur in 80% to 90% of those with infections or malignancy.31 MEASUREMENT OF D-d LEVELS Measurement of D-d levels has been ...
D-dimer concentrations were assessed and compared among different groups. The receiver operating characteristic curve(ROC curve) was established. The potency of D-dimer in distinguishing AMI, non-ST-segment elevation myocardial infarction (NSTEMI) by difference in values was assessed. Results Finally, ...