A new submaximal cycle ergometer test for prediction of VO2max Maximal oxygen uptake (VO2max) is an important, in Bj?rkman,F.,Ekblom-Bak,... - 《Scandinavian Journal of Medicine & Science in Sports》 被引量: 56发表: 2014年 A new valid and reliable windtrainer VO2max protocol Aim. ...
The submaximal cycle protocol required participants to achieve a steady-state heart rate equal to at least 70% of age-predicted maximum heart rate (220-age), while the maximal treadmill graded exercise test required participants to exercise to volitional fatigue. Relevant submaximal cycle ergometer ...
A new submaximal cycle ergometer test for prediction of VO2max. Scand. J. Med. Sci. Sports 24 (2), 319e326.Ekblom-Bak E, Bjorkman F, Hellenius ML, Ekblom B (2014) A new submaximal cycle ergometer test for prediction of VO2max. Scand J Med Sci Sports 24(2):319-326. doi:...
(as'trand-rīm'ing sī'kĕl ĕr-gom'ĕ-tĕr test) A submaximal exercise test used to determine VO2maxin patients with an acute myocardial infarction and high-risk dysrhythmias. See also:Balke-Ware treadmill protocol Medical Dictionary for the Health Professions and Nursing © Farlex 201...
When subjects reached 80% of their cycle ergometer age-predicted maximum heart rate, the test was terminated. Exercise and five-minute recovery heart rate data were collected. A ramp protocol with expired gas analysis was used to measure actual VO 2 max. Multiple regression analysis was u...
Changes in VO2max and Muscular Strength Over A 24-Week Cycle Ergometer Interval Program Among Active Middle-Age Adults: 2212 Board #225 June 1 2: 00 PM - 3: 30 PMInvestigated the effectiveness of participant modeling as a technique for teaching a 12-yr-old educable mentally reta...
cycle ergometer. Exercise intensity was gradually increased and rest periods were gradually decreased so that subjects exercised non-stop for 45 minutes at a heart rate corresponding to approximately 65% of VO2max throughout the training period. At the end of the EET protocol, VO2max was ...
PURPOSE: To determine the intraday and interday reliability of a 2 × 4-min performance test on a cycle ergometer (Wattbike) separated by 30 min of passive recovery (2 × 4MMP). METHODS: Twelve highly trained cyclists (mean ± SD; age = 20 ± 2 y, predicted VO2max = 59.0 ± 3.6 ...
Each subject completed their three exercise trials on a Monark (Model 828 E) bicycle ergometer. For each exercise session, after a warm-up period (30 Watts for 2 min) a pedal rate of 60 rpm was maintained for the remainder of the test. For the first phase the workload was initially se...
The shuttle run test was conducted during regular school hours, usually in the gymnasium. Children were then invited to a lab to complete the cycle ergometer protocol. Children were categorized as possible cases of DCD using the Movement-ABC-2. The analysis was performed using cut-points at ...