DC-CT-1000I current transducer technical specification DC-CT-1000I-S22DA Type Zero-Flux Primary Current Range DC (max) 1000 A Primary Current Range AC rms (max) 700 A Conversion ratio 1:1680 DC Accuracy Nominal Burden Resistance 1Ω (max. 3 Ω) Transformer/Gain Off-Center Error ...
Technical specifications Diameter:35, 24, 70 mm For relay type:RN 5883 Type:ND 5015 Downloads Datasheet RN 5883 (PDF - 464.06 KB) EPLAN macro ND 5015 (ZIP - 141.39 KB) Tender text ND 5015 (TXT - 392 bytes) Features The residual current transformer ND 5015 is designed for DIN rail mo...
- The combined type transformer has various outline dimensions for option; - Adoption of PBT flame-retardant plastic shell; - Epoxy resin casting encapsulation, strong insulation and isolation capability, moisture proof and seismic resistance; Model Specifications Rated Pr.Current ...
一刹那流体,重新起动补救然后闪动rom。 [translate] aParameters determined by the 25 kV current transformer specifications 正在翻译,请等待... [translate] 英语翻译 日语翻译 韩语翻译 德语翻译 法语翻译 俄语翻译 阿拉伯语翻译 西班牙语翻译 葡萄牙语翻译 意大利语翻译 荷兰语翻译 瑞典语翻译 希腊语翻译 51La ...
Safe operation can only be guaranteed if the transducer is used for the purpose, it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associ...
Specifications: Coil Structure: Toroidal Case: PC/UL94-V0 Dielectric Strength: 3.0KV/1mA/1min Output Connection: Terminal Insulation Resistance: DC500V/100MΩ min Measuring Range: 5%In-120%In Features: |Transformer Cu|Transform Electric|Transformer Idw Collection Phase Two Volume 12| **Reliable...
This performance index of the current transformer conforms to the following relevant technical standard: JB/T 10665-2016 JJG 313-2010 Environmental Specifications Table 5-1 Environmental specifications Item Specifications Operating temperature -40°C to +70°C Operating humidity ≤ 95% RH Altitude No...
We want to adjust the transformer and resonant cap specifications to reduce current ripple. Q1) What can be done to reduce the output current ripple? Q2) Besides reducing the output current ripple, is there anything else that needs to...
ZEMCT132 Current Transformer Features: Small size,high accuracy,good consistency Application: for current and power measurement Structural parameter: Front view Bottom view The main technical parameter: Model ZEMCT132 primary current 0~10A(50Ω) secondary current 5mA at inpu...
We provide both design and manufacturing services in-house to create custom transformer solutions that meet specific design specifications. While many transformer companies have shifted to offering only stock items, Straton has continued to be the top choice for customers with complex Indoor and Outdoo...